      <title>Empfehlungen für die Verkabelung von lifepo4 Akkus</title>
      
      
      <link>https://wolf-u.li/empfehlungen-fuer-die-verkabelung-von-lifepo4-akkus/</link>
      <pubDate>Tue, 14 May 2024 09:54:34 +1400</pubDate>
      <guid>https://wolf-u.li/empfehlungen-fuer-die-verkabelung-von-lifepo4-akkus/</guid>
      <description>&lt;p&gt;Wenn man einen LiFePo4 Akku verkabelt, so sollte man darauf achten alles korrekt anzuschließen, Widerstände zu minimieren etc. Auf der Suche nach Empfehlungen bin ich dabei über verschiedene Quellen gestolpert.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;&lt;/p&gt;
&lt;h2 id=&#34;victron-energy---wiring-unlimited&#34;&gt;Victron Energy - Wiring Unlimited&lt;/h2&gt;
&lt;p&gt;In &amp;ldquo;&lt;link rel=dns-prefetch href=//www.victronenergy.de /&gt; &lt;a href=&#34;https://www.victronenergy.de/upload/documents/The_Wiring_Unlimited_book/43562-Wiring_Unlimited-pdf-de.pdf&#34;
    title=&#34;Wiring Unlimited&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Wiring Unlimited&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;&amp;rdquo; hat Victron Energy eine Menge Empfehlungen zusammengeschrieben um die Verdrahtung von elektrischen Systemen, u.a. Batteriebänken, vorzunehmen und so effizient wie möglich zu verbinden.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Wenn man einen LiFePo4 Akku verkabelt, so sollte man darauf achten alles korrekt anzuschließen, Widerstände zu minimieren etc. Auf der Suche nach Empfehlungen bin ich dabei über verschiedene Quellen gestolpert.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins></p>
<h2 id="victron-energy---wiring-unlimited">Victron Energy - Wiring Unlimited</h2>
<p>In &ldquo;<link rel=dns-prefetch href=//www.victronenergy.de /> <a href="https://www.victronenergy.de/upload/documents/The_Wiring_Unlimited_book/43562-Wiring_Unlimited-pdf-de.pdf"
    title="Wiring Unlimited" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Wiring Unlimited&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>&rdquo; hat Victron Energy eine Menge Empfehlungen zusammengeschrieben um die Verdrahtung von elektrischen Systemen, u.a. Batteriebänken, vorzunehmen und so effizient wie möglich zu verbinden.</p>
<h2 id="victron-energy---batteriekabel">Victron Energy - Batteriekabel</h2>
<p>In <link rel=dns-prefetch href=//www.victronenergy.com /> <a href="https://www.victronenergy.com/upload/documents/BatteryCables.pdf"
    title="diesem Dokument" 
     target="_blank" rel="nofollow noopener noreferrer" >
  diesem Dokument&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> gibt Victron Energy Empfehlungen für die Kabelquerschnitte für die Verbindung von Batteriebänken abhängig von der Entfernung.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Anderson Stecker: Empfohlener Kabelquerschnitt</title>
      
      
      <link>https://wolf-u.li/anderson-stecker-empfohlener-kabelquerschnitt/</link>
      <pubDate>Tue, 11 Oct 2022 11:19:04 +1100</pubDate>
      <guid>https://wolf-u.li/anderson-stecker-empfohlener-kabelquerschnitt/</guid>
      <description>&lt;p&gt;Wenn man einen LiFePo4 Akku gelegentlich von seiner Verbindung zum Wechselrichter trennen möchte, kann man einen Anderson Stecker verwenden. Dabei hatte ich mich gefragt welche Kabelquerschnitte eigentlich in die verschiedenen Stecker passen.&lt;/p&gt;
&lt;p&gt;Beim Hersteller fand ich schlussendlich eine &lt;link rel=dns-prefetch href=//www.andersonpower.com /&gt; &lt;a href=&#34;https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/SB175/1s1030a.pdf&#34;
    title=&#34;Tabelle&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Tabelle&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;:&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Wenn man einen LiFePo4 Akku gelegentlich von seiner Verbindung zum Wechselrichter trennen möchte, kann man einen Anderson Stecker verwenden. Dabei hatte ich mich gefragt welche Kabelquerschnitte eigentlich in die verschiedenen Stecker passen.</p>
<p>Beim Hersteller fand ich schlussendlich eine <link rel=dns-prefetch href=//www.andersonpower.com /> <a href="https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/SB175/1s1030a.pdf"
    title="Tabelle" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Tabelle&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>:</p>
<table>
  <thead>
      <tr>
          <th>Belastbarkeit</th>
          <th>AWG</th>
          <th>mm²</th>
          <th>Datenblatt von Anderson</th>
      </tr>
  </thead>
  <tbody>
      <tr>
          <td>50A</td>
          <td>16-6</td>
          <td>1,3-13,3</td>
          <td><link rel=dns-prefetch href=//www.andersonpower.com /> <a href="https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/SB50/ds-sb50.pdf"
    title="Datenblatt" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Datenblatt&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></td>
      </tr>
      <tr>
          <td>120A</td>
          <td>6-1</td>
          <td>13.3 – 42.4</td>
          <td><link rel=dns-prefetch href=//www.andersonpower.com /> <a href="https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/SB120/ds-sb120.pdf"
    title="Datenblatt" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Datenblatt&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></td>
      </tr>
      <tr>
          <td>175A</td>
          <td>12-1/0</td>
          <td>3.3 – 53.5</td>
          <td><link rel=dns-prefetch href=//www.andersonpower.com /> <a href="https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/DS-SB175.pdf"
    title="Datenblatt" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Datenblatt&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></td>
      </tr>
      <tr>
          <td>350A</td>
          <td>1/0-4/0</td>
          <td>53.5 – 107.2</td>
          <td><link rel=dns-prefetch href=//www.andersonpower.com /> <a href="https://www.andersonpower.com/content/dam/app/ecommerce/product-pdfs/SB350/ds-sb350.pdf"
    title="Datenblatt" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Datenblatt&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></td>
      </tr>
  </tbody>
</table>
<p>Interessanterweise scheinen aber in den 175A Stecker auch die 70mm² Kabel zu passen, sofern man diesen vorsichtig schneidet und crimpt (<link rel=dns-prefetch href=//www.meintechblog.de /> <a href="https://www.meintechblog.de/2022/07/operation-hausspeicher-batteriepack-bestuecken/#comment-36958#comment-36958"
    title="Quelle" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Quelle&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>)- empfehlen würde ich es aber nach dem Lesen der Tabelle oben nicht.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Welche Einbaulage ist für prismatische LiFePo4 Zellen optimal?</title>
      
      
      <link>https://wolf-u.li/welche-einbaulage-ist-fuer-prismatische-lifepo4-zellen-optimal/</link>
      <pubDate>Sat, 24 Sep 2022 11:52:55 +2400</pubDate>
      <guid>https://wolf-u.li/welche-einbaulage-ist-fuer-prismatische-lifepo4-zellen-optimal/</guid>
      <description>&lt;p&gt;Auf meiner Reise zur Erforschung von stationären Batterien für den Hausgebrauch hatte ich mir die Frage gestellt, ob es denn erlaubt wäre, die Zellen in einer Lage, in der die Kontakte nicht oben sind, zu montieren. Mir schwebte da die Montage an einer Wand vor, wo es einfacher wäre, wenn man diese liegend montieren könnte. Unten fasse ich meine Erkenntnisse zusammen.&lt;/p&gt;
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
&lt;h2 id=&#34;kopfüber&#34;&gt;Kopfüber&lt;/h2&gt;
&lt;p&gt;Generell ist die Einbaulage &amp;ldquo;kopfüber&amp;rdquo;, also mit den Batteriekontakten nach &amp;ldquo;unten&amp;rdquo; zeigend, als eine unerlaubte Einbaulage anzusehen. Mal davon abgesehen dass man diese auch selten braucht &amp;hellip; ;)&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Auf meiner Reise zur Erforschung von stationären Batterien für den Hausgebrauch hatte ich mir die Frage gestellt, ob es denn erlaubt wäre, die Zellen in einer Lage, in der die Kontakte nicht oben sind, zu montieren. Mir schwebte da die Montage an einer Wand vor, wo es einfacher wäre, wenn man diese liegend montieren könnte. Unten fasse ich meine Erkenntnisse zusammen.</p>
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
<h2 id="kopfüber">Kopfüber</h2>
<p>Generell ist die Einbaulage &ldquo;kopfüber&rdquo;, also mit den Batteriekontakten nach &ldquo;unten&rdquo; zeigend, als eine unerlaubte Einbaulage anzusehen. Mal davon abgesehen dass man diese auch selten braucht &hellip; ;)</p>
<h2 id="liegend">Liegend</h2>
<p>Die liegende Lage ist zunächst sehr abhängig vom Hersteller. Generell wird in fast allen Foren und Beiträgen erstmal davon abgeraten, solange der Hersteller dies nicht explizit freigibt. Ließt man sich beispielsweise das Datenblatt der <a href="/upload/2022/09/LF280K_3.2V_280Ah.pdf"
    title="EVE LF280K" 
   >
  EVE LF280K</a> durch, so sieht man dort keinen Hinweis auf Einbaulage. CALB hingegen <a href="/upload/2022/09/CALB_User_Manual.pdf"
    title="schreibt" 
   >
  schreibt</a> explizit:</p>
<blockquote>
<p>Placing the battery on its <strong>side is not recommended</strong>, installing the battery <strong>upside down is prohibited</strong></p>
</blockquote>
<p>Aus Erfahrung von anderen Nutzern der EVE LF280K Zellen kann man jedoch ableiten:</p>
<ul>
<li>Generell ist eine stehenden Lage gegenüber der liegenden Lage vorzuziehen</li>
<li>Kippt man die Zelle sanft hin und her und hört dabei ein &ldquo;Gluckern&rdquo; so sollte man diese Zellen nicht liegend/seitlich lagern (auch wenn man sich da streitet ob das wirklich ein Thema ist)</li>
<li>Möchten man die Zellen unbedingt liegend montieren, so sollte dies mit einer schmalen Seite nach unten geschehen</li>
<li>Von der Nutzung der breiten Seite für die Montage ist abzuraten.</li>
</ul>
<h2 id="mehr-infos">Mehr Infos</h2>
<p>Ich fand das nachfolgende Video recht hilfreich für die Recherche - zudem wird dort auch der Aufbau der Zellen erläutert:</p>
<div style="position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden;">
      <iframe allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share; fullscreen" loading="eager" referrerpolicy="strict-origin-when-cross-origin" src="https://www.youtube-nocookie.com/embed/-GbsYTd1_os?autoplay=0&amp;controls=1&amp;end=0&amp;loop=0&amp;mute=0&amp;start=0" style="position: absolute; top: 0; left: 0; width: 100%; height: 100%; border:0;" title="YouTube video"></iframe>