<?xml version="1.0" encoding="utf-8" standalone="yes"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/">
  <channel>
    <title>Ulis Notizen</title>
    <link>https://wolf-u.li/</link>
    <description>Recent content on Ulis Notizen</description>
    <generator>Hugo</generator>
    <language>de</language>
    <copyright>Copyright 2006-CURRENTYEAR Uli Wolf - All rights reserved</copyright>
    <lastBuildDate>Sun, 08 Feb 2026 19:54:44 +0800</lastBuildDate>
    <atom:link href="https://wolf-u.li/index.xml" rel="self" type="application/rss+xml" />
    <item>
      <title>Fensterkontakt für Roto R8 Dachfenster</title>
      
      
      <link>https://wolf-u.li/fensterkontakt-fuer-roto-r8-dachfenster/</link>
      <pubDate>Sun, 08 Feb 2026 19:54:44 +0800</pubDate>
      <guid>https://wolf-u.li/fensterkontakt-fuer-roto-r8-dachfenster/</guid>
      <description>&lt;p&gt;Mein neues Roto Dachfenster brauchte einen Fensterkontakt für KNX Automationen und dafür machte ich mich auf die Suche nach den Möglichkeiten. Leider hatte ich beim Einbau vergessen dies anzufragen (Roto baut dies auch Werkseitig für rund 150 Euro (Stand 2026) ein) sodass ich nun eine Nachrüstung vornehmen musste.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Auf meiner Suche stolperte ich über den passenden &lt;link rel=dns-prefetch href=//knx-user-forum.de /&gt; &lt;a href=&#34;https://knx-user-forum.de/forum/%C3%B6ffentlicher-bereich/knx-eib-forum/16964-roto-r8-dachfenster-fensterkontakt&#34;
    title=&#34;Thread&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Thread&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; im KNX-User-Forum, wo dies thematisiert wurde. Nach einigem Hin- und Her ging ich wie folgt vor:&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Mein neues Roto Dachfenster brauchte einen Fensterkontakt für KNX Automationen und dafür machte ich mich auf die Suche nach den Möglichkeiten. Leider hatte ich beim Einbau vergessen dies anzufragen (Roto baut dies auch Werkseitig für rund 150 Euro (Stand 2026) ein) sodass ich nun eine Nachrüstung vornehmen musste.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Auf meiner Suche stolperte ich über den passenden <link rel=dns-prefetch href=//knx-user-forum.de /> <a href="https://knx-user-forum.de/forum/%C3%B6ffentlicher-bereich/knx-eib-forum/16964-roto-r8-dachfenster-fensterkontakt"
    title="Thread" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Thread&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> im KNX-User-Forum, wo dies thematisiert wurde. Nach einigem Hin- und Her ging ich wie folgt vor:</p>
<p>Kaufliste:</p>
<ul>
<li>
<a href="https://www.amazon.de/dp/B00109M2X8?tag=lebendeswolfuli-21" target="_blank">Bosch Professional 1x HSS-G Metallbohrer Ø 4 mm, 119 mm Gesamtlänge*</a>
</li>
<li>Link 1001017A, Magnetkontakt flach, VDS 4-adrig, 4m Kabel, weiß - manchmal auf 
<a href="https://www.ebay.de/sch/i.html?_nkw=Link&#43;1001017A&mkcid=1&mkrid=707-53477-19255-0&siteid=77&campid=5336433624&customid=&toolid=10001&mkevt=1" target="_blank">eBay*</a>
 verfügbar.</li>
<li>
<a href="https://www.amazon.de/dp/B00MPIFD4I?tag=lebendeswolfuli-21" target="_blank">SPAX Universalschraube, 3x16 mm*</a>
 oder 
<a href="https://www.amazon.de/dp/B09QX8F8WX?tag=lebendeswolfuli-21" target="_blank">Spax Universalschraube, 3x20 mm*</a>
</li>
<li>Was zum Abdichten - ich hatte noch eine Tube 
<a href="https://www.amazon.de/dp/B09N7FVNFF?tag=lebendeswolfuli-21" target="_blank">Sikaflex 522*</a>
 da aber da geht bestimmt auch anderes</li>
</ul>
<p>Für das rausmessen der Kontaktleitungen braucht man noch ein 
<a href="https://www.amazon.de/s?k=Multimeter&tag=lebendeswolfuli-21" target="_blank">Multimeter*</a>
, für die Montage natürlich was zum Messen (ich habe einen 
<a href="https://www.amazon.de/s?k=Messschieber&tag=lebendeswolfuli-21" target="_blank">Messschieber*</a>
 genutzt), einen Stift (z.B. den 
<a href="https://www.amazon.de/dp/B002X7Y90U?tag=lebendeswolfuli-21" target="_blank">Pica 3030 Dry*</a>
) und zum Bohren/Schrauben praktischerweise einen Akkuschrauber (Ich nutze einen 
<a href="https://www.amazon.de/dp/B07RCJNLJV?tag=lebendeswolfuli-21" target="_blank">Bosch GSR 12V-35 FC*</a>
).</p>
<ul>
<li>Los geht&rsquo;s mit dem Montageort, welcher links oder rechts sein kann.</li>
<li>Öffne das Fenster, dann lokalisiere den Schließblock (Schwarz auf dem Rahmen).</li>
<li>Messe dort bis zum potentiellen Loch des Reedkontakts (bei mir waren es 27mm) und markiere passend. Das Loch selbst konnte beim Link 1001017A gerade in die vorhandene Nut gebohrt werden.
<img src="/upload/2026/02/roto-r8-kontakt-1.webp" alt="Montageort" loading="lazy"></li>
<li>Nimm den langen 4mm Bohrer, dann bohre zunächst gerade nach unten um durch das erste Profil zu kommen.</li>
<li>Dann bohre schräg (WICHTIG!!!) nach Innen um hinter die Verkleidungsplatte aber vor die Abdichtung zu kommen.</li>
<li>Nun kann das Kabel durchgeführt werden. Das sieht dann so aus:
<img src="/upload/2026/02/roto-r8-kontakt-2.webp" alt="Kabel Durchführung unten" loading="lazy">
<img src="/upload/2026/02/roto-r8-kontakt-3.webp" alt="Kabel Durchführung oben" loading="lazy"></li>
<li>Bevor du den Magnet fest schraubst, solltest du das Profil wieder um das Loch oben und unten abdichten.</li>
<li>Nun kommt das Messgerät/Multimeter zum Einsatz. Finde zunächst raus, welche zwei Adern für den Reedkontakt sind (zwei bleiben unabhängig vom Magneten immer geschlossen (&ldquo;Sabotagekontakt&rdquo;) und zwei Adern werden abhängig von der Position des Magneten geschlossen), dann drehe den Magneten so dass er den Reedkontakt schließt wenn er aufliegt.</li>
<li>Klemme den Magneten genau hinter die Schließvorrichtung in die Flügelnut und schließe bei eingeschaltetem Multimeter das Fenster - dies sollte nun auch einen geschlossenen Reedkontakt anzeigen. Wenn nicht, dann Magnet nochmal raus und 180 Grad drehen.</li>
<li>Nun den Magnet noch fest schrauben
<img src="/upload/2026/02/roto-r8-kontakt-4.webp" alt="Kabel Durchführung oben" loading="lazy"></li>
<li>Fertig :-)</li>
</ul>
<p>Im Thread wurden auch noch Optionen für eine Verschlusserkennung thematisiert - das wurde mir aber zu kompliziert, weshalb ich das so nicht gemacht hatte.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Fritz!Box 7590 AX auf Fritz!Box 5690 Pro umziehen</title>
      
      
      <link>https://wolf-u.li/fritzbox-7590ax-auf-fritzbox-5690-pro-umziehen/</link>
      <pubDate>Sun, 07 Dec 2025 10:06:20 +0700</pubDate>
      <guid>https://wolf-u.li/fritzbox-7590ax-auf-fritzbox-5690-pro-umziehen/</guid>
      <description>&lt;p&gt;Heute wollte ich den Umzug von meiner Fritz!Box 7590 AX auf die neue Fritz!Box 5690 Pro durchführen. Dazu bietet AVM einen tollen &lt;link rel=dns-prefetch href=//fritz.com /&gt; &lt;a href=&#34;https://fritz.com/service/wissensdatenbank/dok/FRITZ-Box-5690-Pro/3743_Einstellungen-auf-eine-neue-FRITZ-Box-ubertragen/&#34;
    title=&#34;Wechsel-Assistent&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Wechsel-Assistent&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; (Oder hier als &lt;link rel=dns-prefetch href=//www.youtube.com /&gt; &lt;a href=&#34;https://www.youtube.com/watch?v=NeBdePj5Ebo&#34;
    title=&#34;Video&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Video&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; erläutert), welcher bei mir genau nicht funktioniert hat. Warum?
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Der Wechselassistent klingt zu toll:&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Heute wollte ich den Umzug von meiner Fritz!Box 7590 AX auf die neue Fritz!Box 5690 Pro durchführen. Dazu bietet AVM einen tollen <link rel=dns-prefetch href=//fritz.com /> <a href="https://fritz.com/service/wissensdatenbank/dok/FRITZ-Box-5690-Pro/3743_Einstellungen-auf-eine-neue-FRITZ-Box-ubertragen/"
    title="Wechsel-Assistent" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Wechsel-Assistent&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> (Oder hier als <link rel=dns-prefetch href=//www.youtube.com /> <a href="https://www.youtube.com/watch?v=NeBdePj5Ebo"
    title="Video" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Video&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> erläutert), welcher bei mir genau nicht funktioniert hat. Warum?
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Der Wechselassistent klingt zu toll:</p>
<ul>
<li>Verbinden: Schließe die neue FRITZ!Box an, verbindet sich mit einem Netzwerkkabel zum vorhandenen Netzwerk / Fritz!Box</li>
<li>Assistent starten: Öffne die Benutzeroberfläche (fritz.box) der neuen Box und klicke links unten auf Assistenten.</li>
<li>Umzug wählen: Wähle &ldquo;Einstellungen auf eine neue FRITZ!Box übertragen&rdquo; und folge den Anweisungen.</li>
<li>Alte Box sichern: Die neue Box führt durch das Sichern der Einstellungen von der alten Box.</li>
<li>Einstellungen übertragen: Die Daten werden von der alten auf die neue Box übertragen.</li>
<li>Umstecken: Trennen die alte Box vom Strom, wenn die neue fertig ist, und stecke alle Geräte an die neue Box.</li>
</ul>
<p>Und dann kam der Fehler&hellip;</p>
<blockquote>
<p>Das installierte FRITZ!OS Ihrer neuen FRITZ!Box 5690 Pro ist zu alt und es steht auch keine aktuellere FRITZ!OS-Version zur Verfügung.
Die Einstellungen Ihrer bisherigen FRITZ!Box können nicht auf Ihre neue FRITZ!Box übertragen werden.</p>
</blockquote>
<p>Es ist recht schnell erklärt. Während meine Fritz!Box 7590 AX bereits Firmware Version 8.20 hat, ist die Fritz!Box 5690 Pro derzeit nur auf 8.03. Das führt dazu dass man leider den Wechselassistent nicht nutzen kann, auch wenn die Fritz!Box 5690 Pro deutlich neuer ist als die bisherige 7590 AX.</p>
<p>Nach dem ersten Versuch des Wechselassistenten muss man zunächst die Verbindung zwischen den beiden Trennen und die neue Fritz!Box 5690 Pro auf Werkseinstellungen resetten.</p>
<ul>
<li>Nun navigiert man zum <link rel=dns-prefetch href=//www.mengelke.de /> <a href="https://www.mengelke.de/Projekte/FritzBox-JSTool"
    title="Fritz!Box JSTool" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Fritz!Box JSTool&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> und importiert dort die Sicherung welche während dem Wechsel erstellt wurde.</li>
<li>Unter FirmwareVersion (Relativ weit oben in der Datei) die Versionsnummer auf 259.08.20 ändern (also z.B. FirmwareVersion=154.08.20 zu FirmwareVersion=279.08.03). Die Versionsnummern habe ich von <link rel=dns-prefetch href=//www.router-faq.de /> <a href="https://www.router-faq.de/?id=fbinfo&amp;hwf=fb5690pro#fb5630#fb5630"
    title="hier" 
     target="_blank" rel="nofollow noopener noreferrer" >
  hier&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>.</li>
<li>&ldquo;Calc&rdquo; oder &ldquo;Berechnen&rdquo; klicken, damit eine neu Checksum berechnet wird.</li>
<li>&ldquo;Save&rdquo; oder &ldquo;Speichern&rdquo; drücken, um die angepasste Version herunterzuladen</li>
<li>In der FRITZ!Box 5690 Pro die neu gespeicherte Sicherung importieren</li>
</ul>
<p><img src="/upload/2025/12/fritzbox-7590ax-auf-fritzbox-5690-pro-umziehen-1.webp" alt="WT32-ETH01 Flashen" loading="lazy"></p>
<p>Nach dem Neustart und Umstecken der Kabel auf die neue Fritz!Box müssen nun die Repeater &amp; Telefone neu angemeldet werden, was aber mit einigem Drücken der Connect Taste schnell erledigt ist.</p>
]]></content:encoded>
    </item>
    <item>
      <title>ASRock DeskMini 310: Tot? Keine LED? Keine Geräusche? Lösung</title>
      
      
      <link>https://wolf-u.li/asrock-deskmini-310-tot-keine-led-keine-ger%C3%A4usche-loesung/</link>
      <pubDate>Mon, 10 Feb 2025 09:16:28 +1000</pubDate>
      <guid>https://wolf-u.li/asrock-deskmini-310-tot-keine-led-keine-ger%C3%A4usche-loesung/</guid>
      <description>&lt;p&gt;Ich habe zwei AsRock DeskMini 310 für meine interne Virtualisierung in meinem Homelab. Die Dinger sind recht zuverlässig und sparsam (was der Grund ist, warum ich diese gewählt habe), aber manchmal, wenn sie mal aus sind, gehen sie einfach nicht wieder an. Symptome sind dass weder eine LED zu sehen noch ein Lüfter hörbar ist. Er startet einfach nicht und bleibt aus. Und weil das gestern wieder passiert ist, habe ich mir gedacht, ich schreibe mal einen Blog-Eintrag darüber ;-)
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Beim ersten Mal war es zum Verrückt werden. Wir hatten einen Stromausfall und danach wollte der DeskMini 310 einfach nicht mehr hochfahren. Was ich alles probiert habe:&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Ich habe zwei AsRock DeskMini 310 für meine interne Virtualisierung in meinem Homelab. Die Dinger sind recht zuverlässig und sparsam (was der Grund ist, warum ich diese gewählt habe), aber manchmal, wenn sie mal aus sind, gehen sie einfach nicht wieder an. Symptome sind dass weder eine LED zu sehen noch ein Lüfter hörbar ist. Er startet einfach nicht und bleibt aus. Und weil das gestern wieder passiert ist, habe ich mir gedacht, ich schreibe mal einen Blog-Eintrag darüber ;-)
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Beim ersten Mal war es zum Verrückt werden. Wir hatten einen Stromausfall und danach wollte der DeskMini 310 einfach nicht mehr hochfahren. Was ich alles probiert habe:</p>
<ul>
<li>Netzteil durchgemessen, war alles in Ordnung (und es hat wie immer gepfiffen)</li>
<li>Eine Weile den Stecker gezogen</li>
<li>Festplatten abgeklemmt, Speicher gewechselt</li>
</ul>
<p>Hat alles leider keinen Effekt gehabt. Irgendwann ist mir dann ein alter Trick eingefallen, der mir mal bei einem alten PC geholfen hat (ich glaube, das war ein Pentium 133 Mhz oder so): <strong>Die BIOS-Batterie rausnehmen! Und das hat geholfen!</strong></p>
<p>Also, so geht&rsquo;s:</p>
<ul>
<li>Netzteil und alle anderen Kabel (z.B. Netzwerk) abziehen.</li>
<li>Gehäuse von hinten aufschrauben (4 Schrauben).</li>
<li>Mainboard rausholen – vorsichtig mit den internen Kabeln!</li>
<li>Mainboard losschrauben (4 Schrauben, eine in jeder Ecke).</li>
<li>Mainboard vorsichtig an der Seite anheben, die normalerweise nach vorne zeigt.</li>
<li>Dann vorsichtig nach vorne ziehen, damit die Anschlüsse aus der Rückwandplatte kommen. Vorsicht, falls du eine SATA-Platte angeschlossen hast!</li>
<li>Unter dem Mainboard findest du das Kabel der BIOS-Batterie. Abziehen und 10 Sekunden warten.</li>
<li>BIOS-Batterie wieder einstecken.</li>
<li>Mainboard vorsichtig wieder in die Rückwandplatte schieben, dabei das Mainboard leicht anwinkeln.</li>
<li>Die vier Schrauben des Mainboards wieder festziehen.</li>
<li>Mainboard vorsichtig wieder ins Gehäuse schieben. Denk dran, das Kabel zu den Frontanschlüssen wieder anzuschließen, falls du es abgezogen hast.</li>
<li>Die vier Schrauben des Gehäuses wieder festziehen.</li>
</ul>
<p>Wenn man nun den DeskMini dann wieder einschaltet, sieht man, dass er alle BIOS-Einstellungen (inklusive der Uhrzeit) vergessen hat, aber wenigstens geht er wieder an ;-)</p>
]]></content:encoded>
    </item>
    <item>
      <title>Wie schneidet man Estrich mit einem Winkelschleifer</title>
      
      
      <link>https://wolf-u.li/wie-schneidet-man-estrich-mit-einem-winkelschleifer/</link>
      <pubDate>Sun, 19 Jan 2025 21:22:56 +1900</pubDate>
      <guid>https://wolf-u.li/wie-schneidet-man-estrich-mit-einem-winkelschleifer/</guid>
      <description>&lt;p&gt;Im Rahmen einer Sanierung stellte ich mir die Frage wie man denn den Estrich schneiden könnte. Es gibt natürlich verschiedene Methoden und Werkzeuge dazu.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Das wichtigste ist erstmal: Egal, welches Werkzeug man nimmt - schütze immer dich selbst mit einer ordentlichen 
&lt;a href=&#34;https://www.amazon.de/dp/B00EJIMZT8?tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Atemschutzmaske*&lt;/a&gt;
, 
&lt;a href=&#34;https://www.amazon.de/s?k=Schutzbrille&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Schutzbrille*&lt;/a&gt;
, Gehörschutz und sorge dafür dass eine Absaugung bereitsteht und verwendet wird.&lt;/p&gt;
&lt;p&gt;Kommen wir also zum Werkzeug. Estrich schneidet man gerne mit einem Diamanttrennscheibe. Dieses wird im Regelfall in einem Winkelschleifer (im Profi-Bereich auch mit einer Betonsäge), wie z.b. dem 
&lt;a href=&#34;https://www.amazon.de/s?k=Makita%20GA9050R&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Makita GA9050R*&lt;/a&gt;
 eingespannt.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Im Rahmen einer Sanierung stellte ich mir die Frage wie man denn den Estrich schneiden könnte. Es gibt natürlich verschiedene Methoden und Werkzeuge dazu.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Das wichtigste ist erstmal: Egal, welches Werkzeug man nimmt - schütze immer dich selbst mit einer ordentlichen 
<a href="https://www.amazon.de/dp/B00EJIMZT8?tag=lebendeswolfuli-21" target="_blank">Atemschutzmaske*</a>
, 
<a href="https://www.amazon.de/s?k=Schutzbrille&tag=lebendeswolfuli-21" target="_blank">Schutzbrille*</a>
, Gehörschutz und sorge dafür dass eine Absaugung bereitsteht und verwendet wird.</p>
<p>Kommen wir also zum Werkzeug. Estrich schneidet man gerne mit einem Diamanttrennscheibe. Dieses wird im Regelfall in einem Winkelschleifer (im Profi-Bereich auch mit einer Betonsäge), wie z.b. dem 
<a href="https://www.amazon.de/s?k=Makita%20GA9050R&tag=lebendeswolfuli-21" target="_blank">Makita GA9050R*</a>
 eingespannt.</p>
<p>Wenn man aber nun in den Estrich schneidet, so wird viel Staub entstehen. Daher empfiehlt es sich den Winkelschleifer mit einer passenden Absaugung zu versehen. Im Falle des Makita GA9050R wäre das beispielsweise die 
<a href="https://www.amazon.de/dp/B07C5VBPXX?tag=lebendeswolfuli-21" target="_blank">Makita 198440-5 Absaughaube*</a>
, welche dies ermöglich würde und zudem auch die Schnitttiefe regulieren kann. Einziger Wermutstropfen ist, dass hier keine Vorrichtung zum Einhängen in eine Führungsschiene vorhanden ist. Natürlich gibt&rsquo;s das auch für andere 230mm Winkelschleifer, z.b. von 
<a href="https://www.amazon.de/dp/B07ZNLVRG9?tag=lebendeswolfuli-21" target="_blank">Fanztool*</a>
</p>
<p>Warum nimmt man nicht einfach eine Tauchsäge mit einer Diamanttrennscheibe? Theoretisch kann man das machen aber man sollte dabei bedenken, dass zum einen der feine Staub des Estrichs später auf weiteren feinen Holzschnitten immer seine Spuren hinterlassen wird (Kratzer etc.) und dass eine Tauchsäge meist deutlich teurer als die Kombination von Winkelschleifer und Absaughaube ist.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Berechnung von Druckverlust in Leitungen (z.B. Trinkwasser) und Rohren</title>
      
      
      <link>https://wolf-u.li/berechnung-von-druckverlust-in-leitungen-trinkwasser-und-rohren/</link>
      <pubDate>Wed, 15 Jan 2025 10:08:54 +1500</pubDate>
      <guid>https://wolf-u.li/berechnung-von-druckverlust-in-leitungen-trinkwasser-und-rohren/</guid>
      <description>&lt;p&gt;Im Rahmen einer Sanierung von diversen Leitungen kam die Frage auf, welcher Durchmesser für diverse Leitungen bzw. Rohre notwendig ist, um einen bestimmten Druck durch das Haus mit möglichst wenig Druckverlust zu transportieren.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;&lt;/p&gt;
&lt;p&gt;Nach etwas Recherche fand ich die folgenden zwei Seiten, welche dies einfach online durchführen:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;link rel=dns-prefetch href=//www.druckverlust.online /&gt; &lt;a href=&#34;http://www.druckverlust.online/&#34;
    title=&#34;http://www.druckverlust.online/&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  http://www.druckverlust.online/&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;&lt;/li&gt;
&lt;li&gt;&lt;link rel=dns-prefetch href=//druckgefaelle-rechner.viega.de /&gt; &lt;a href=&#34;https://druckgefaelle-rechner.viega.de/&#34;
    title=&#34;https://druckgefaelle-rechner.viega.de/&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  https://druckgefaelle-rechner.viega.de/&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Ich hatte mich für ersteren entschieden und konnte so schnell die notwendigen Anbindungen für z.b. Trinkwasser oder Heizung berechnen.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Im Rahmen einer Sanierung von diversen Leitungen kam die Frage auf, welcher Durchmesser für diverse Leitungen bzw. Rohre notwendig ist, um einen bestimmten Druck durch das Haus mit möglichst wenig Druckverlust zu transportieren.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins></p>
<p>Nach etwas Recherche fand ich die folgenden zwei Seiten, welche dies einfach online durchführen:</p>
<ul>
<li><link rel=dns-prefetch href=//www.druckverlust.online /> <a href="http://www.druckverlust.online/"
    title="http://www.druckverlust.online/" 
     target="_blank" rel="nofollow noopener noreferrer" >
  http://www.druckverlust.online/&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></li>
<li><link rel=dns-prefetch href=//druckgefaelle-rechner.viega.de /> <a href="https://druckgefaelle-rechner.viega.de/"
    title="https://druckgefaelle-rechner.viega.de/" 
     target="_blank" rel="nofollow noopener noreferrer" >
  https://druckgefaelle-rechner.viega.de/&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></li>
</ul>
<p>Ich hatte mich für ersteren entschieden und konnte so schnell die notwendigen Anbindungen für z.b. Trinkwasser oder Heizung berechnen.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Verbindung von Wickelfalzrohren (Spiro)</title>
      
      
      <link>https://wolf-u.li/verbindung-von-wickelfalzrohren/</link>
      <pubDate>Mon, 06 Jan 2025 07:50:03 +0600</pubDate>
      <guid>https://wolf-u.li/verbindung-von-wickelfalzrohren/</guid>
      <description>&lt;p&gt;Derzeit verbaue ich einen Schwung Wickelfalzrohre, auch &amp;ldquo;Spiro&amp;rdquo; genannt. Dafür beschreibt die DIN VDE 0100-410 in Abschnitt 413.1.2.1 dass u.a. auch &amp;ldquo;Metallteile der Gebäudekonstruktion, Zentralheizungs- und Klimaanlagen&amp;rdquo; als fremde leitfähige Teile mit der Potentialausgleichsschiene zu einem Hauptpotentialausgleich verbunden werden. Generell sind in einem Haus auch andere leitfähige Teile, wie metallene Wasserleitungen, Abwasserleitungen oder Gasleitungen an den Potentialausgleich anzuschließen. Und somit eben auch die Wickelfalzrohre.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Bei meiner Anlage verwende ich zumeist Wickelfalzrohren mit Gummidichtung. Da die übergangswiderstände zwischen den einzelnen Rohrelementen niederohmig sein müssen, kann die sichere elektrische Verbindung nicht nur durch &amp;ldquo;festes&amp;rdquo; zusammenstecken der Rohre gewährleistet werden, sondern muss zusätzlich durch &amp;ldquo;geeignete Maßnamen&amp;rdquo; ergänzt werden. Diese kann beispielsweise eine Verschraubung, Vernietung oder sogar eine Verbindung über 
&lt;a href=&#34;https://www.amazon.de/s?k=Erdungsrohrschelle&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Erdungs(band)rohrschellen*&lt;/a&gt;
 sein.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Derzeit verbaue ich einen Schwung Wickelfalzrohre, auch &ldquo;Spiro&rdquo; genannt. Dafür beschreibt die DIN VDE 0100-410 in Abschnitt 413.1.2.1 dass u.a. auch &ldquo;Metallteile der Gebäudekonstruktion, Zentralheizungs- und Klimaanlagen&rdquo; als fremde leitfähige Teile mit der Potentialausgleichsschiene zu einem Hauptpotentialausgleich verbunden werden. Generell sind in einem Haus auch andere leitfähige Teile, wie metallene Wasserleitungen, Abwasserleitungen oder Gasleitungen an den Potentialausgleich anzuschließen. Und somit eben auch die Wickelfalzrohre.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Bei meiner Anlage verwende ich zumeist Wickelfalzrohren mit Gummidichtung. Da die übergangswiderstände zwischen den einzelnen Rohrelementen niederohmig sein müssen, kann die sichere elektrische Verbindung nicht nur durch &ldquo;festes&rdquo; zusammenstecken der Rohre gewährleistet werden, sondern muss zusätzlich durch &ldquo;geeignete Maßnamen&rdquo; ergänzt werden. Diese kann beispielsweise eine Verschraubung, Vernietung oder sogar eine Verbindung über 
<a href="https://www.amazon.de/s?k=Erdungsrohrschelle&tag=lebendeswolfuli-21" target="_blank">Erdungs(band)rohrschellen*</a>
 sein.</p>
<p>Für die dichte Verbindung von Wickelfalzrohren habe ich diese zwei Methoden als die am besten geeigneten gefunden:</p>
<ul>
<li>Profilverbinderschrauben</li>
<li>Dichtblindnieten</li>
</ul>
<p>Bei den 
<a href="https://www.amazon.de/dp/B0D6BWCZHM?tag=lebendeswolfuli-21" target="_blank">Profilverbinderschrauben*</a>
 handelt es sich um spezielle Schrauben mit einer Bohrspitze und einem Feingewinde, welche sich in das Blech bohren und dabei aber nicht zu viel Material verdrängen. Ich habe phosphatierte verwendet, da diese einen Schutz vor Korrosion mitbringen - keine Ahnung, ob das wirklich notwendig ist. Durch die Bohrspitze kommen die Schrauben durch dünnes Blech (in meinem Fall 0,6mm) ohne Vorbohren, was die Verarbeitungsgeschwindigkeit deutlich erhöht. Bei dickeren Materialien kann man 
<a href="https://www.amazon.de/dp/B0D6BX54Q1?tag=lebendeswolfuli-21" target="_blank">Schrauben mit Bohrspitze*</a>
 verwenden - hier muss man aber drauf achten, dass der Bohrer recht kurz ist um nicht zu viel Material zu verdrängen. Ein Hinweis noch: Für eine eventuelle spätere Reinigung sind die Schrauben natürlich etwas hinderlich - da braucht man dann das passende Werkzeug.</p>
<p>Die zweite Möglichkeit ist, die Verbindung zu nieten. Dabei sollte man auf druckdichte Nieten, sogenannte 
<a href="https://www.amazon.de/s?k=Dichtblindnieten&tag=lebendeswolfuli-21" target="_blank">Dichtblindnieten*</a>
 achten. Diese bleiben dicht, da der innere Splint nicht rausfällt. Generell ist die Montage leider etwas komplizierter, da man bohren und nieten in zwei Schritten machen muss. Dafür kann man hinterher die Rohre leichter reinigen, da die Nieten innen recht dünn nur auftragen.</p>
<p>Quellen:</p>
<ul>
<li><link rel=dns-prefetch href=//www.elektropraktiker.de /> <a href="https://www.elektropraktiker.de/fachartikel/detail/potentialausgleich-von-lueftungsrohren"
    title="Potentialausgleich von Lüftungsrohren" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Potentialausgleich von Lüftungsrohren&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></li>
<li><link rel=dns-prefetch href=//www.ateam-ffm.de /> <a href="https://www.ateam-ffm.de/files/fachtagungen/2017/20170103_Schauer_Erdung%20und%20Potentialausgleich%20in%20elektrischen%20Anlagen_aTeam.pdf"
    title="Erdung und Potentialausgleich in elektrischen Anlagen" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Erdung und Potentialausgleich in elektrischen Anlagen&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></li>
<li><link rel=dns-prefetch href=//itsolution.lindab.com /> <a href="https://itsolution.lindab.com/lindabwebproductsdoc/pdf/de/mounting/safe_click.pdf"
    title="Montageanweisung Lindab Safe und Lindab Safe Click" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Montageanweisung Lindab Safe und Lindab Safe Click&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a></li>
</ul>
]]></content:encoded>
    </item>
    <item>
      <title>Welcher Dübel für welche Stockschraubengröße?</title>
      
      
      <link>https://wolf-u.li/welcher-d%C3%BCbel-f%C3%BCr-welche-stockschraubengroesse/</link>
      <pubDate>Sun, 05 Jan 2025 23:29:04 +0500</pubDate>
      <guid>https://wolf-u.li/welcher-d%C3%BCbel-f%C3%BCr-welche-stockschraubengroesse/</guid>
      <description>&lt;p&gt;Heute habe ich mal wieder nach langer Zeit Stockschrauben montiert und bin dabei auf die Frage gestoßen, welcher Dübel für welche Stockschraubengröße geeignet ist. Aber zunächst - was ist eigentlich eine Stockschraube?
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Eine Stockschraube ist eine spezielle Schraube, die zwei verschiedene Gewindearten kombiniert. Auf der einen Seite hat sie ein Holzgewinde (meist ein grobes, spitzes Gewinde), das in Materialien wie Holz oder Dübel geschraubt wird. Auf der anderen Seite befindet sich ein metrisches Gewinde, das für Muttern oder andere Verbindungen geeignet ist. Stockschrauben werden oft verwendet, um Gegenstände wie Halterungen oder Rohrschellen an Wänden zu befestigen. Sie bieten eine stabile Verbindung zwischen verschiedenen Materialien. Zum Eindrehen der Stockschraube wird häufig ein Torx-Bit, Schraubenschlüssel, 
&lt;a href=&#34;https://www.amazon.de/s?k=Stockschraubendreher&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Stockschraubendreher*&lt;/a&gt;
 oder eine Zange verwendet.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Heute habe ich mal wieder nach langer Zeit Stockschrauben montiert und bin dabei auf die Frage gestoßen, welcher Dübel für welche Stockschraubengröße geeignet ist. Aber zunächst - was ist eigentlich eine Stockschraube?
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Eine Stockschraube ist eine spezielle Schraube, die zwei verschiedene Gewindearten kombiniert. Auf der einen Seite hat sie ein Holzgewinde (meist ein grobes, spitzes Gewinde), das in Materialien wie Holz oder Dübel geschraubt wird. Auf der anderen Seite befindet sich ein metrisches Gewinde, das für Muttern oder andere Verbindungen geeignet ist. Stockschrauben werden oft verwendet, um Gegenstände wie Halterungen oder Rohrschellen an Wänden zu befestigen. Sie bieten eine stabile Verbindung zwischen verschiedenen Materialien. Zum Eindrehen der Stockschraube wird häufig ein Torx-Bit, Schraubenschlüssel, 
<a href="https://www.amazon.de/s?k=Stockschraubendreher&tag=lebendeswolfuli-21" target="_blank">Stockschraubendreher*</a>
 oder eine Zange verwendet.</p>
<p>Ich möchte nun also Rohrschellen an einer Ziegelwand befestigen - welche Größe der Dübel sollte ich verwenden? Meine persönliche Tabelle ist hierzu die folgende (ich übernehme keine Haftung dafür - prüfe immer ob dein verwendeter Dübel die Stockschraube aufnehmen kann BEVOR du bohrst):</p>
<table>
  <thead>
      <tr>
          <th>Dübelgröße (mm)</th>
          <th>Stockschraubengröße</th>
      </tr>
  </thead>
  <tbody>
      <tr>
          <td>8</td>
          <td>M6</td>
      </tr>
      <tr>
          <td>10</td>
          <td>M8</td>
      </tr>
      <tr>
          <td>12</td>
          <td>M10</td>
      </tr>
      <tr>
          <td>14</td>
          <td>M12</td>
      </tr>
  </tbody>
</table>
<p>Meist verwende ich dazu die 
<a href="https://www.amazon.de/s?k=Fischer%20DuoPower&tag=lebendeswolfuli-21" target="_blank">Fischer DuoPower*</a>
 Dübel, da bei diese einen weiten Radius von Untergründen abdecken. Der Hersteller bezeichnet diese als &ldquo;intelligent&rdquo;, da die beiden verwendeten Materialien zur hohen Haltekraft führen. Der harte Teil sorgt für Stabilität, der weiche Teil passt sich dem Untergrund an. Dadurch funktionieren die Dübel in nahezu allen Baustoffen (z. B. Beton, Ziegel, Gips) ohne dass man sich einen Kopf machen muss. Und aus meiner Erfahrung hält selbst bei nicht perfekt gebohrten Löchern (passiert halt manchmal) der Dübel dennoch - daher meine klare Empfehlung. Wo wir grad beim Bohren sind: Der richtige Bohrer für den Untergrund ist immer noch wichtig ;-)</p>
<p>Ich verwende allerdings diese Befestigungsvariante (Dübel und Stockschraube) ausschließlich an Wanden. Für die Betondecke nehme ich immer 
<a href="https://www.amazon.de/s?k=Bolzenanker&tag=lebendeswolfuli-21" target="_blank">Bolzenanker*</a>
 (manchmal auch unter &ldquo;Schwerlastanker&rdquo; zu finden) da diese im Brandfall nicht schmelzen (wie Kunststoffdübel eben) und herunterfallen können und speziell für besonders harte Materialien wie Beton (Decken eben) geeignet sind.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Kombiniertes Kabel für 230v und KNX</title>
      
      
      <link>https://wolf-u.li/kombiniertes-kabel-fuer-230v-und-knx/</link>
      <pubDate>Thu, 03 Oct 2024 20:39:21 +0300</pubDate>
      <guid>https://wolf-u.li/kombiniertes-kabel-fuer-230v-und-knx/</guid>
      <description>&lt;p&gt;In meinem Renovierungsprojekt verlege ich derzeit KNX neben 230V Leitungen. Zumeist kann ich das grüne Kabel und die NYM Leitung nebeneinander problemlos legen. Was aber wenn man einen Spezialfall hat wo das nicht geht?
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
In diesem Falle könnte man von Lapp das UNITRONIC® BUS EIB COMBI Kabel mit der Artikelnummer 2170242 einsetzen. Dieses beinhaltet 2x2x0,8 mm (also ein KNX Kabel) und 3x1,5 mm²	(also die NYM-Leitung) in einem Kabel von 12,7mm Aussendurchmesser.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>In meinem Renovierungsprojekt verlege ich derzeit KNX neben 230V Leitungen. Zumeist kann ich das grüne Kabel und die NYM Leitung nebeneinander problemlos legen. Was aber wenn man einen Spezialfall hat wo das nicht geht?
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
In diesem Falle könnte man von Lapp das UNITRONIC® BUS EIB COMBI Kabel mit der Artikelnummer 2170242 einsetzen. Dieses beinhaltet 2x2x0,8 mm (also ein KNX Kabel) und 3x1,5 mm²	(also die NYM-Leitung) in einem Kabel von 12,7mm Aussendurchmesser.</p>
<p>Sehr praktische Lösung.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Gira Steckdose mit LED-Orientierungsleuchte (z.b. 417003) - Bilder und Ansichten</title>
      
      
      <link>https://wolf-u.li/gira-steckdose-mit-led-leuchte-417003/</link>
      <pubDate>Tue, 21 May 2024 10:34:00 +2100</pubDate>
      <guid>https://wolf-u.li/gira-steckdose-mit-led-leuchte-417003/</guid>
      <description>&lt;p&gt;Heute werfe ich einen genaueren Blick auf die &lt;link rel=dns-prefetch href=//katalog.gira.de /&gt; &lt;a href=&#34;https://katalog.gira.de/de_DE/datenblatt.html?id=797454&#34;
    title=&#34;Gira Steckdose mit LED-Licht&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Gira Steckdose mit LED-Licht&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;. Diese bietet am unteren Rand der Steckdose ein paar LED Lichtpunkte welche deinen Weg in der Dämmerung/Nacht erhellen können.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Die Gira Steckdose mit LED-Licht hebt sich durch ihre integrierte Beleuchtung von herkömmlichen Steckdosen ab. Die LEDs sind in den Rahmen der Steckdose integriert, leuchten nach unten und bieten so eine dezente Beleuchtung. Dies kann besonders nützlich sein, wenn Du nachts eine Orientierungshilfe benötigst.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Heute werfe ich einen genaueren Blick auf die <link rel=dns-prefetch href=//katalog.gira.de /> <a href="https://katalog.gira.de/de_DE/datenblatt.html?id=797454"
    title="Gira Steckdose mit LED-Licht" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Gira Steckdose mit LED-Licht&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>. Diese bietet am unteren Rand der Steckdose ein paar LED Lichtpunkte welche deinen Weg in der Dämmerung/Nacht erhellen können.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Die Gira Steckdose mit LED-Licht hebt sich durch ihre integrierte Beleuchtung von herkömmlichen Steckdosen ab. Die LEDs sind in den Rahmen der Steckdose integriert, leuchten nach unten und bieten so eine dezente Beleuchtung. Dies kann besonders nützlich sein, wenn Du nachts eine Orientierungshilfe benötigst.</p>
<p><strong>Achtung</strong>: Bei Elektroarbeiten ist Vorsicht geboten, damit Sicherheitsaspekte und gesetzliche Vorgaben berücksichtigt und eingehalten werden. Die fünf Sicherheitsregeln sind einzuhalten (<strong>Freischalten</strong>, <strong>Gegen Wiedereinschalten sichern</strong>, <strong>Spannungsfreiheit feststellen</strong>, <strong>Erden und kurzschließen</strong> und das <strong>Abdecken oder Abschranken von benachbarten unter Spannung stehenden Teilen</strong>) um sicher hier arbeiten zu können.</p>
<h2 id="bilder">Bilder</h2>
<p><img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-1.webp" alt="Übersicht" loading="lazy">
<img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-2.webp" alt="Übersicht" loading="lazy">
<img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-3.webp" alt="Übersicht" loading="lazy"></p>
<h2 id="installation">Installation</h2>
<p>Die Installation dieser Steckdose ist unkompliziert und erfordert keine besonderen technischen Kenntnisse. Wenn du eine Gira-Steckdose aus den letzten Jahren hast, kannst du einfach nur die Abdeckung tauschen und die beiden Stifte werden an der richtigen Position einrasten. So muss nicht die gesamte Steckdose getauscht werden. Wenn du eine ältere Steckdose hast, so muss auch die Steckdose an sich getauscht werden. Da die GIRA Steckdose an sich eine &ldquo;ganz normale&rdquo; ist, passt diese in jede Standard-Unterputzdose, sodass Du sie problemlos gegen eine herkömmliche Steckdose austauschen kannst.</p>
<p><img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-4.webp" alt="Übersicht" loading="lazy">
<img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-5.webp" alt="Übersicht" loading="lazy">
<img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-6.webp" alt="Übersicht" loading="lazy">
<img src="/upload/2024/05/gira-steckdose-mit-led-leuchte-417003-7.webp" alt="Übersicht" loading="lazy"></p>
<h2 id="betrieb">Betrieb</h2>
<p>Die LED-Leuchten mit einer Leuchtkraft von 0.2 cd werden sich nur bei Dunkelheit aktivieren. Dies wird über einen integrierten Helligkeitssensor gesteuert, welchen du über das Abdecken des kleinen Sichtauges forcieren kannst. Leider hat die Steckdose keinen Bewegungssensor, sodass das Licht bei Dunkelheit immer leuchtet, egal ob es benötigt wird oder nicht.</p>
<h2 id="fazit">Fazit</h2>
<p>Bei Dunkelheit konnte ich keine aussagekräftigen Bilder schießen. Generell wird der Weg erleuchtet und man kann dies als Orientierungsleuchte verwenden. Allerdings war für mich die Tatsache, dass das Licht wirklich die ganze Nacht durch leuchtet, leider nicht akzeptabel. Dies war weniger aufgrund des Stromverbrauchs (welcher mit 0,25W wirklich nicht hoch ist) sondern aufgrund des dauerhaften Lichtes welches genau in den Schlafraum leuchtete. Daher verwende ich diese Leuchte nicht.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Empfehlungen für die Verkabelung von lifepo4 Akkus</title>
      
      
      <link>https://wolf-u.li/empfehlungen-fuer-die-verkabelung-von-lifepo4-akkus/</link>
      <pubDate>Tue, 14 May 2024 09:54:34 +1400</pubDate>
      <guid>https://wolf-u.li/empfehlungen-fuer-die-verkabelung-von-lifepo4-akkus/</guid>
      <description>&lt;p&gt;Wenn man einen LiFePo4 Akku verkabelt, so sollte man darauf achten alles korrekt anzuschließen, Widerstände zu minimieren etc. Auf der Suche nach Empfehlungen bin ich dabei über verschiedene Quellen gestolpert.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;&lt;/p&gt;
&lt;h2 id=&#34;victron-energy---wiring-unlimited&#34;&gt;Victron Energy - Wiring Unlimited&lt;/h2&gt;
&lt;p&gt;In &amp;ldquo;&lt;link rel=dns-prefetch href=//www.victronenergy.de /&gt; &lt;a href=&#34;https://www.victronenergy.de/upload/documents/The_Wiring_Unlimited_book/43562-Wiring_Unlimited-pdf-de.pdf&#34;
    title=&#34;Wiring Unlimited&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Wiring Unlimited&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt;&amp;rdquo; hat Victron Energy eine Menge Empfehlungen zusammengeschrieben um die Verdrahtung von elektrischen Systemen, u.a. Batteriebänken, vorzunehmen und so effizient wie möglich zu verbinden.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Wenn man einen LiFePo4 Akku verkabelt, so sollte man darauf achten alles korrekt anzuschließen, Widerstände zu minimieren etc. Auf der Suche nach Empfehlungen bin ich dabei über verschiedene Quellen gestolpert.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins></p>
<h2 id="victron-energy---wiring-unlimited">Victron Energy - Wiring Unlimited</h2>
<p>In &ldquo;<link rel=dns-prefetch href=//www.victronenergy.de /> <a href="https://www.victronenergy.de/upload/documents/The_Wiring_Unlimited_book/43562-Wiring_Unlimited-pdf-de.pdf"
    title="Wiring Unlimited" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Wiring Unlimited&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a>&rdquo; hat Victron Energy eine Menge Empfehlungen zusammengeschrieben um die Verdrahtung von elektrischen Systemen, u.a. Batteriebänken, vorzunehmen und so effizient wie möglich zu verbinden.</p>
<h2 id="victron-energy---batteriekabel">Victron Energy - Batteriekabel</h2>
<p>In <link rel=dns-prefetch href=//www.victronenergy.com /> <a href="https://www.victronenergy.com/upload/documents/BatteryCables.pdf"
    title="diesem Dokument" 
     target="_blank" rel="nofollow noopener noreferrer" >
  diesem Dokument&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> gibt Victron Energy Empfehlungen für die Kabelquerschnitte für die Verbindung von Batteriebänken abhängig von der Entfernung.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Sensus 620 Wasserzähler: Smart machen via ESPHome</title>
      
      
      <link>https://wolf-u.li/sensus-620-wasserzaehler-smart-machen/</link>
      <pubDate>Sat, 17 Feb 2024 13:23:59 +1700</pubDate>
      <guid>https://wolf-u.li/sensus-620-wasserzaehler-smart-machen/</guid>
      <description>&lt;p&gt;Vor kurzem habe ich meinen Wasserzähler, einen Sensus 620 &amp;ldquo;smart&amp;rdquo; gemacht, was eigentlich relativ einfach war. Mein Ziel war eine einfache Einbindung in Home Assistant.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Eine kurze Suche im Netz brachte mir zu einer Seite auf Printables, wo ein passendes 3D-Modell angeboten wurde, welches zusammen mit einen NPN-Sensor und einen ESP8266 die Impulse des Wasserzählers auszulesen versprach. Dafür wurde ESPHome eingesetzt.&lt;/p&gt;
&lt;p&gt;Dazu braucht man:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Wemos D1 ESP8266: 
&lt;a href=&#34;http://s.click.aliexpress.com/e/_DBfU38z&#34;&gt;Aliexpress*&lt;/a&gt;
 / 
&lt;a href=&#34;https://www.amazon.de/s?k=Wemos%20D1%20ESP8266&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Amazon*&lt;/a&gt;
&lt;/li&gt;
&lt;li&gt;NPN 5V Sensor: 
&lt;a href=&#34;http://s.click.aliexpress.com/e/_DDiiVVX&#34;&gt;Aliexpress*&lt;/a&gt;
 / 
&lt;a href=&#34;https://www.amazon.de/s?k=npn%205v&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Amazon*&lt;/a&gt;
&lt;/li&gt;
&lt;li&gt;10K Widerstand: 
&lt;a href=&#34;http://s.click.aliexpress.com/e/_De2Ecv3&#34;&gt;Aliexpress*&lt;/a&gt;
 / 
&lt;a href=&#34;https://www.amazon.de/s?k=10K%20Widerstand&amp;tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Amazon*&lt;/a&gt;
&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Und natürlich das ausgedruckte 3D-Modell. Den ESP8266 muss man dann mit Hilfe der Website &lt;link rel=dns-prefetch href=//huizebruin.github.io /&gt; &lt;a href=&#34;https://huizebruin.github.io/s0tool/&#34;
    title=&#34;s0tool&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  s0tool&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; flashen (Besuche diese mit Chrome oder Edge!). Das bringt zum einen ESPHome auf den ESP8266 aber konfiguriert auch eine entsprechende Schnittstelle für den NPN-Sensor.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Vor kurzem habe ich meinen Wasserzähler, einen Sensus 620 &ldquo;smart&rdquo; gemacht, was eigentlich relativ einfach war. Mein Ziel war eine einfache Einbindung in Home Assistant.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Eine kurze Suche im Netz brachte mir zu einer Seite auf Printables, wo ein passendes 3D-Modell angeboten wurde, welches zusammen mit einen NPN-Sensor und einen ESP8266 die Impulse des Wasserzählers auszulesen versprach. Dafür wurde ESPHome eingesetzt.</p>
<p>Dazu braucht man:</p>
<ul>
<li>Wemos D1 ESP8266: 
<a href="http://s.click.aliexpress.com/e/_DBfU38z">Aliexpress*</a>
 / 
<a href="https://www.amazon.de/s?k=Wemos%20D1%20ESP8266&tag=lebendeswolfuli-21" target="_blank">Amazon*</a>
</li>
<li>NPN 5V Sensor: 
<a href="http://s.click.aliexpress.com/e/_DDiiVVX">Aliexpress*</a>
 / 
<a href="https://www.amazon.de/s?k=npn%205v&tag=lebendeswolfuli-21" target="_blank">Amazon*</a>
</li>
<li>10K Widerstand: 
<a href="http://s.click.aliexpress.com/e/_De2Ecv3">Aliexpress*</a>
 / 
<a href="https://www.amazon.de/s?k=10K%20Widerstand&tag=lebendeswolfuli-21" target="_blank">Amazon*</a>
</li>
</ul>
<p>Und natürlich das ausgedruckte 3D-Modell. Den ESP8266 muss man dann mit Hilfe der Website <link rel=dns-prefetch href=//huizebruin.github.io /> <a href="https://huizebruin.github.io/s0tool/"
    title="s0tool" 
     target="_blank" rel="nofollow noopener noreferrer" >
  s0tool&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> flashen (Besuche diese mit Chrome oder Edge!). Das bringt zum einen ESPHome auf den ESP8266 aber konfiguriert auch eine entsprechende Schnittstelle für den NPN-Sensor.</p>
<p>Das Verkabelungsschema findet man auf der Webseite - das ganze ist relativ easy. Dort ist auch gezeigt, wie man dann den absoluten Wert ändert und das ganze in ESPHome auf Home Assistant einbindet.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Paperless-ngx ASN mit Avery L4731 labels</title>
      
      
      <link>https://wolf-u.li/paperless-ngx-asn-mit-avery-l4731-labels/</link>
      <pubDate>Wed, 24 Jan 2024 08:40:09 +2400</pubDate>
      <guid>https://wolf-u.li/paperless-ngx-asn-mit-avery-l4731-labels/</guid>
      <description>&lt;p&gt;In der heutigen digitalen Ära ist die effiziente Verwaltung von Dokumenten entscheidend. In diesem Kontext spielt paperless-ngx eine entscheidende Rolle, indem es eine innovative Lösung für die nahtlose Integration von physischen und digitalisierten Dokumenten bietet.&lt;/p&gt;
&lt;p&gt;Paperless-ngx, ein fortschrittliches Dokumentenmanagementsystem, ermöglicht es Nutzern, die Vorteile der Digitalisierung zu nutzen, ohne dabei den Bezug zu physischen Dokumenten zu verlieren. Die Herausforderung besteht oft darin, eine Verbindung zwischen den traditionellen Papierdokumenten und ihrer digitalen Kopie herzustellen. Für diese Verknüpfung von physikalischen Unterlagen und den digitalisierten Dokumenten in &lt;link rel=dns-prefetch href=//docs.paperless-ngx.com /&gt; &lt;a href=&#34;https://docs.paperless-ngx.com/&#34;
    title=&#34;paperless-ngx&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  paperless-ngx&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; bietet es sich an, &lt;link rel=dns-prefetch href=//docs.paperless-ngx.com /&gt; &lt;a href=&#34;https://docs.paperless-ngx.com/advanced_usage/#barcodes#barcodes&#34;
    title=&#34;Barcodes&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  Barcodes&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; zu verwenden um die ASN (Archive Serial Number) noch vor dem Scannen bereits festzulegen.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Nach dem Einsatz eines Scanners (Sei es ein 
&lt;a href=&#34;https://www.amazon.de/dp/B07H3B9Z7Q?tag=lebendeswolfuli-21&#34; target=&#34;_blank&#34;&gt;Brother ADS-1700W*&lt;/a&gt;
 wie in meinem Fall oder einfach eine Handy-Kamera) verwandelt paperless-ngx Papier in durchsuchbare (dank OCR) und editierbare digitale Formate. Paperless-ngx klassifiziert anschließend das Dokument. So wird automatisiert festgestellt mit wem diese Korrespondenz gelaufen ist oder welche Tags der paperless-ngx Nutzer üblicherweise vergibt wenn ähnliche Dokumente gescannt werden.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>In der heutigen digitalen Ära ist die effiziente Verwaltung von Dokumenten entscheidend. In diesem Kontext spielt paperless-ngx eine entscheidende Rolle, indem es eine innovative Lösung für die nahtlose Integration von physischen und digitalisierten Dokumenten bietet.</p>
<p>Paperless-ngx, ein fortschrittliches Dokumentenmanagementsystem, ermöglicht es Nutzern, die Vorteile der Digitalisierung zu nutzen, ohne dabei den Bezug zu physischen Dokumenten zu verlieren. Die Herausforderung besteht oft darin, eine Verbindung zwischen den traditionellen Papierdokumenten und ihrer digitalen Kopie herzustellen. Für diese Verknüpfung von physikalischen Unterlagen und den digitalisierten Dokumenten in <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/"
    title="paperless-ngx" 
     target="_blank" rel="nofollow noopener noreferrer" >
  paperless-ngx&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> bietet es sich an, <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/advanced_usage/#barcodes#barcodes"
    title="Barcodes" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Barcodes&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> zu verwenden um die ASN (Archive Serial Number) noch vor dem Scannen bereits festzulegen.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Nach dem Einsatz eines Scanners (Sei es ein 
<a href="https://www.amazon.de/dp/B07H3B9Z7Q?tag=lebendeswolfuli-21" target="_blank">Brother ADS-1700W*</a>
 wie in meinem Fall oder einfach eine Handy-Kamera) verwandelt paperless-ngx Papier in durchsuchbare (dank OCR) und editierbare digitale Formate. Paperless-ngx klassifiziert anschließend das Dokument. So wird automatisiert festgestellt mit wem diese Korrespondenz gelaufen ist oder welche Tags der paperless-ngx Nutzer üblicherweise vergibt wenn ähnliche Dokumente gescannt werden.</p>
<p>Paperless kann zudem vorhandene Barcodes auf dem Dokument auslesen. Die Idee ist, dass man für physikalische Dokumente, welche aufgehoben werden sollen, eine aufsteigende Nummer vergibt und dann alle eingehenden Dokumente einfach zeitlich nacheinander in einem Ordner aufbewahrt. Habe ich nun den Bedarf, ein bestimmtes Dokument physikalisch zu erhalten, so kann ich in paperless-ngx nachsehen, welche Nummer (z.B. 1337) dafür vergeben ist und ziehe den entsprechenden Ordner (z.b. Ordner mit Dokumenten 1350-1400) raus und finde es dort direkt. Paperless-ngx nennt diese Nummer dann ASN (Archive Serial Number).</p>
<p>Um nun die Vergabe der ASN zu beschleunigen wird die ASN auf einem Aufkleber vorgedruckt und dann direkt beim Scan des Dokuments in Paperless verfügbar (sofern dies via Environment Variable <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/configuration/#PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE#PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE"
    title="PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE" 
     target="_blank" rel="nofollow noopener noreferrer" >
  PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> aktiviert wurde). Dies sieht dann so aus:
<img src="/upload/2024/01/paperless-ngx-asn-mit-avery-l4731-labels-1.webp" alt="Paperless-ngx ASN" loading="lazy"></p>
<p>Diese ASN hat einen spezifischen Prefix - In der Standard-Ausführung von paperless-ngx ist dies <code>ASN</code>, kann aber über die Umgebungsvariable <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/configuration/#PAPERLESS_CONSUMER_ASN_BARCODE_PREFIX#PAPERLESS_CONSUMER_ASN_BARCODE_PREFIX"
    title="PAPERLESS_CONSUMER_ASN_BARCODE_PREFIX" 
     target="_blank" rel="nofollow noopener noreferrer" >
  PAPERLESS_CONSUMER_ASN_BARCODE_PREFIX&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> abgeändert werden. Einige schlaue Köpfe in der <link rel=dns-prefetch href=//github.com /> <a href="https://github.com/paperless-ngx/paperless-ngx/discussions/4588"
    title="Community" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Community&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> haben sich nun verschiedene Lösungen für die Aufkleber ausgedacht, welche sich im Regelfall um die 
<a href="https://www.amazon.de/dp/B0002S48QC?tag=lebendeswolfuli-21" target="_blank">Avery L4731REV-25*</a>
 drehen.</p>
<ul>
<li>Generierung des PDF für den Druck via Website:<br />Diese Ansatz nutzt eine <link rel=dns-prefetch href=//tobiasmaier.info /> <a href="https://tobiasmaier.info/asn-qr-code-label-generator/"
    title="Website" 
     target="_blank" rel="nofollow noopener noreferrer" >
  Website&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> auf der man die Labels vor-generieren kann. Dies ist eigentlich selbsterklärend.</li>
<li>Generierung des PDF via python Script:<br />Dieser Ansatz nutzt ein python Script und generiert darüber das PDF. Hier gibts verschiedene Lösungen:
<ul>
<li>jcgruenhage&rsquo;s <link rel=dns-prefetch href=//git.jcg.re /> <a href="https://git.jcg.re/jcgruenhage/paperless-asn-qr-codes"
    title="paperless-asn-qr-codes" 
     target="_blank" rel="nofollow noopener noreferrer" >
  paperless-asn-qr-codes&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a><br />Installation: <code>pip install paperless-asn-qr-codes</code><br />Generierung: <code>pipx run paperless-asn-qr-codes 1 asn-1to189.pdf</code></li>
<li>gitolicious&rsquo;s <link rel=dns-prefetch href=//github.com /> <a href="https://github.com/gitolicious/avery-asn/"
    title="avery-asn" 
     target="_blank" rel="nofollow noopener noreferrer" >
  avery-asn&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a><br />Installation: <code>git clone https://github.com/gitolicious/avery-asn.git</code><br />Generierung habe ich nicht probiert - hier scheinen aber auch weitere Label-Typen möglich zu sein.</li>
</ul>
</li>
</ul>
<p>Nun druckt man also dieses generierte PDF auf ein entsprechendes Label-Sheet. Nach der Aktivierung von <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/configuration/#PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE#PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE"
    title="PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE" 
     target="_blank" rel="nofollow noopener noreferrer" >
  PAPERLESS_CONSUMER_ENABLE_ASN_BARCODE&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> kann nun bei künftigen Scans die entsprechende Nummer direkt in paperless eingetragen werden.</p>
]]></content:encoded>
    </item>
    <item>
      <title>Paperless-ngx: Erneutes tagging von Dokumenten</title>
      
      
      <link>https://wolf-u.li/paperless-ngx-erneutes-tagging-von-dokumenten/</link>
      <pubDate>Fri, 08 Dec 2023 13:07:58 +0800</pubDate>
      <guid>https://wolf-u.li/paperless-ngx-erneutes-tagging-von-dokumenten/</guid>
      <description>&lt;p&gt;Wenn man eine Weile lang die automatische Klassifizierung von Dokumenten in paperless-ngx trainiert hat, möchte man diesen natürlich auch auf alle ausstehenden Dokumente anwenden. Da diese bei Eingang eines Dokuments (also via dem Consumer Verzeichnis, Email oder API) klassifiziert werden muss man sich eines Kniffs behelfen.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Zunächst würde ich das Neural Network neu trainieren um alle Dokumenten-Klassifikationen im Matching-Algorithmus zu haben:&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;1
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-bash&#34; data-lang=&#34;bash&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;document_create_classifier
&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;&lt;p&gt;Anschließend kann man den Retagger laufen lassen. Nutze dafür diese Zeile, die genauen Details sind aber &lt;link rel=dns-prefetch href=//docs.paperless-ngx.com /&gt; &lt;a href=&#34;https://docs.paperless-ngx.com/administration/#retagger#retagger&#34;
    title=&#34;hier&#34; 
     target=&#34;_blank&#34; rel=&#34;nofollow noopener noreferrer&#34; &gt;
  hier&amp;nbsp;&lt;svg xmlns=&#34;http://www.w3.org/2000/svg&#34; class=&#34;icon&#34; aria-hidden=&#34;true&#34; focusable=&#34;false&#34; viewBox=&#34;0 -128 512 640&#34;&gt;
    &lt;path d=&#34;M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z&#34;/&gt;
  &lt;/svg&gt;&lt;/a&gt; beschrieben:&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Wenn man eine Weile lang die automatische Klassifizierung von Dokumenten in paperless-ngx trainiert hat, möchte man diesen natürlich auch auf alle ausstehenden Dokumente anwenden. Da diese bei Eingang eines Dokuments (also via dem Consumer Verzeichnis, Email oder API) klassifiziert werden muss man sich eines Kniffs behelfen.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Zunächst würde ich das Neural Network neu trainieren um alle Dokumenten-Klassifikationen im Matching-Algorithmus zu haben:</p>
<div class="highlight"><div class="chroma">
<table class="lntable"><tr><td class="lntd">
<pre tabindex="0" class="chroma"><code><span class="lnt">1
</span></code></pre></td>
<td class="lntd">
<pre tabindex="0" class="chroma"><code class="language-bash" data-lang="bash"><span class="line"><span class="cl">document_create_classifier
</span></span></code></pre></td></tr></table>
</div>
</div><p>Anschließend kann man den Retagger laufen lassen. Nutze dafür diese Zeile, die genauen Details sind aber <link rel=dns-prefetch href=//docs.paperless-ngx.com /> <a href="https://docs.paperless-ngx.com/administration/#retagger#retagger"
    title="hier" 
     target="_blank" rel="nofollow noopener noreferrer" >
  hier&nbsp;<svg xmlns="http://www.w3.org/2000/svg" class="icon" aria-hidden="true" focusable="false" viewBox="0 -128 512 640">
    <path d="M384 320c-17.67 0-32 14.33-32 32v96H64V160h96c17.67 0 32-14.32 32-32s-14.33-32-32-32L64 96c-35.35 0-64 28.65-64 64V448c0 35.34 28.65 64 64 64h288c35.35 0 64-28.66 64-64v-96C416 334.3 401.7 320 384 320zM488 0H352c-12.94 0-24.62 7.797-29.56 19.75c-4.969 11.97-2.219 25.72 6.938 34.88L370.8 96L169.4 297.4c-12.5 12.5-12.5 32.75 0 45.25C175.6 348.9 183.8 352 192 352s16.38-3.125 22.62-9.375L416 141.3l41.38 41.38c9.156 9.141 22.88 11.84 34.88 6.938C504.2 184.6 512 172.9 512 160V24C512 10.74 501.3 0 488 0z"/>
  </svg></a> beschrieben:</p>
<div class="highlight"><div class="chroma">
<table class="lntable"><tr><td class="lntd">
<pre tabindex="0" class="chroma"><code><span class="lnt">1
</span></code></pre></td>
<td class="lntd">
<pre tabindex="0" class="chroma"><code class="language-bash" data-lang="bash"><span class="line"><span class="cl">document_retagger --correspondent --tags --document_type --storage_path --inbox-only --use-first -f
</span></span></code></pre></td></tr></table>
</div>
</div>]]></content:encoded>
    </item>
    <item>
      <title>Paperless-ngx: Startseite konfigurieren</title>
      
      
      <link>https://wolf-u.li/paperless-ngx-startseite-konfigurieren/</link>
      <pubDate>Fri, 08 Dec 2023 13:07:58 +0800</pubDate>
      <guid>https://wolf-u.li/paperless-ngx-startseite-konfigurieren/</guid>
      <description>&lt;p&gt;Wenn man einen Blick in ein frisches paperless-ngx wirft, so ist die Startseite relativ leer:&lt;/p&gt;
&lt;p&gt;&lt;img src=&#34;https://wolf-u.li/upload/2023/12/paperless-ngx-startseite-konfigurieren-1.webp&#34; alt=&#34;Startseite&#34; loading=&#34;lazy&#34;&gt;&lt;/p&gt;
&lt;p&gt;&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Ich wollte die neu eingegangenen Dokumente anzeigen lassen. Dies ist relativ einfach - in der Ansicht Dokumente konfiguriert man sich die passende Ansicht und geht dann rechts oben auf das Speichern der Ansicht.&lt;/p&gt;
&lt;p&gt;&lt;img src=&#34;https://wolf-u.li/upload/2023/12/paperless-ngx-startseite-konfigurieren-2.webp&#34; alt=&#34;Startseite&#34; loading=&#34;lazy&#34;&gt;&lt;/p&gt;
&lt;p&gt;&lt;img src=&#34;https://wolf-u.li/upload/2023/12/paperless-ngx-startseite-konfigurieren-3.webp&#34; alt=&#34;Startseite&#34; loading=&#34;lazy&#34;&gt;&lt;/p&gt;
&lt;p&gt;Dort kann man dann auswählen ob diese Ansicht auf der Startseite angezeigt wird.&lt;/p&gt;</description>
      
         <content:encoded><![CDATA[<p>Wenn man einen Blick in ein frisches paperless-ngx wirft, so ist die Startseite relativ leer:</p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-1.webp" alt="Startseite" loading="lazy"></p>
<p><ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Ich wollte die neu eingegangenen Dokumente anzeigen lassen. Dies ist relativ einfach - in der Ansicht Dokumente konfiguriert man sich die passende Ansicht und geht dann rechts oben auf das Speichern der Ansicht.</p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-2.webp" alt="Startseite" loading="lazy"></p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-3.webp" alt="Startseite" loading="lazy"></p>
<p>Dort kann man dann auswählen ob diese Ansicht auf der Startseite angezeigt wird.</p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-4.webp" alt="Startseite" loading="lazy"></p>
<p>Und schon sieht die Startseite nicht mehr so leer aus:</p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-5.webp" alt="Startseite" loading="lazy"></p>
<p>Will man eine Ansicht umkonfigurieren so ist dies über die Einstellungen möglich:</p>
<p><img src="/upload/2023/12/paperless-ngx-startseite-konfigurieren-6.webp" alt="Startseite" loading="lazy"></p>
]]></content:encoded>
    </item>
    <item>
      <title>Homeassistant: Übersetzung des Fronius Wechselrichter Status Code</title>
      
      
      <link>https://wolf-u.li/homeassistant-uebersetzung-des-fronius-wechselrichter-status-code/</link>
      <pubDate>Sat, 25 Nov 2023 20:58:30 +2500</pubDate>
      <guid>https://wolf-u.li/homeassistant-uebersetzung-des-fronius-wechselrichter-status-code/</guid>
      <description>&lt;p&gt;Vor einiger Zeit habe ich für meinen Fronius Solar Wechselrichter ein Template in Home-Assistant für eine Übersetzung des Status Codes gebaut.
&lt;ins class=&#34;adsbygoogle&#34; style=&#34;display:block; text-align:center;&#34; data-ad-layout=&#34;in-article&#34; data-ad-format=&#34;fluid&#34; data-ad-client=&#34;ca-pub-2322978122735420&#34; data-ad-slot=&#34;3161252284&#34;&gt;&lt;/ins&gt;
Damit bekommt man nicht nur kryptische Zahlen ausgeworfen, sondern kann sogar was damit anfangen ;-) Im Untenstehenden Template musst du nur deinen sensor für den Status Code statt meinem &lt;code&gt;sensor.status_code_fronius_inverter&lt;/code&gt; eintragen.&lt;/p&gt;
&lt;div class=&#34;highlight&#34;&gt;&lt;div class=&#34;chroma&#34;&gt;
&lt;table class=&#34;lntable&#34;&gt;&lt;tr&gt;&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code&gt;&lt;span class=&#34;lnt&#34;&gt;  1
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  2
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  3
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  4
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  5
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  6
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  7
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  8
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;  9
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 10
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 11
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 12
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 13
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 14
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 15
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 16
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 17
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 18
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 19
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 20
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 21
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 22
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 23
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 24
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 25
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 26
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 27
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 28
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 29
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 30
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 31
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 32
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 33
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 34
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 35
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 36
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 37
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 38
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 39
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 40
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 41
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 42
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 43
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 44
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 45
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 46
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 47
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 48
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 49
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 50
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 51
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 52
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 53
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 54
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 55
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 56
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 57
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 58
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 59
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 60
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 61
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 62
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 63
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 64
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 65
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 66
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 67
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 68
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 69
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 70
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 71
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 72
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 73
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 74
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 75
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 76
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 77
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 78
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 79
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 80
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 81
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 82
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 83
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 84
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 85
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 86
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 87
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 88
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 89
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 90
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 91
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 92
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 93
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 94
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 95
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 96
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 97
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 98
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt; 99
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;100
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;101
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;102
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;103
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;104
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;105
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;106
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;107
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;108
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;109
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;110
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;111
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;112
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;113
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;114
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;115
&lt;/span&gt;&lt;span class=&#34;lnt&#34;&gt;116
&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;
&lt;td class=&#34;lntd&#34;&gt;
&lt;pre tabindex=&#34;0&#34; class=&#34;chroma&#34;&gt;&lt;code class=&#34;language-yaml&#34; data-lang=&#34;yaml&#34;&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;nn&#34;&gt;---&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;nt&#34;&gt;template&lt;/span&gt;&lt;span class=&#34;p&#34;&gt;:&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;w&#34;&gt;  &lt;/span&gt;- &lt;span class=&#34;nt&#34;&gt;sensor&lt;/span&gt;&lt;span class=&#34;p&#34;&gt;:&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;w&#34;&gt;      &lt;/span&gt;- &lt;span class=&#34;nt&#34;&gt;name&lt;/span&gt;&lt;span class=&#34;p&#34;&gt;:&lt;/span&gt;&lt;span class=&#34;w&#34;&gt; &lt;/span&gt;&lt;span class=&#34;s2&#34;&gt;&amp;#34;Fronius Status Message&amp;#34;&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;w&#34;&gt;        &lt;/span&gt;&lt;span class=&#34;nt&#34;&gt;state&lt;/span&gt;&lt;span class=&#34;p&#34;&gt;:&lt;/span&gt;&lt;span class=&#34;w&#34;&gt; &lt;/span&gt;&lt;span class=&#34;p&#34;&gt;&amp;gt;&lt;/span&gt;&lt;span class=&#34;sd&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% if is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;102&amp;#39; ) %}AC-Spannung zu hoch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;103&amp;#39; ) %}AC-Spannung zu gering
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;105&amp;#39; ) %}AC-Frequenz zu hoch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;106&amp;#39; ) %}AC-Frequenz zu gering
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;107&amp;#39; ) %}AC-Netz nicht vorhanden
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;108&amp;#39; ) %}Inselbetrieb erkannt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;112&amp;#39; ) %}Fehler RCMU
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;301&amp;#39; ) %}Überstrom (AC) 
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;302&amp;#39; ) %}Überstrom (DC)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;303&amp;#39; ) %}Übertemperatur DC Modul
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;304&amp;#39; ) %}Übertemperatur AC Modul
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;305&amp;#39; ) %}Keine Einspeisung trotz geschlossener Relais
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;306&amp;#39; ) %}Es steht zu wenig PV-Leistung für den Einspeisebetrieb zur Verfügung
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;307&amp;#39; ) %}DC-Eingangsspannung zu gering für den Einspeisebetrieb
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;308&amp;#39; ) %}Zwischenkreisspannung zu hoch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;309&amp;#39; ) %}DC-Eingangsspannung MPPT 1 zu hoch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;311&amp;#39; ) %}DC-Stränge verpolt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;313&amp;#39; ) %}DC-Eingangsspannung MPPT2 zu hoch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;314&amp;#39; ) %}Timeout Stromsensor-Kalibrierung
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;315&amp;#39; ) %}AC Stromsensor Fehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;316&amp;#39; ) %}InterruptCheck fail
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;325&amp;#39; ) %}Übertemperatur im Anschlussbereich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;326&amp;#39; ) %}Lüfter 1 Fehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;327&amp;#39; ) %}Lüfter 2 Fehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;401&amp;#39; ) %}Kommunikation mit dem Leistungsteil nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;406&amp;#39; ) %}Temperatursensor AC Modul defekt (L1)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;407&amp;#39; ) %}Temperatursensor AC Modul defekt (L2)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;408&amp;#39; ) %}Zu hoher Gleichanteil im Versorgungsnetz gemessen
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;412&amp;#39; ) %}Der Fix-Spannungsbetrieb ist statt des MPP-Spannungsbetriebes angewählt und die Fixspannung ist auf einen zu geringen oder zu hohen Wert eingestellt.
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;415&amp;#39; ) %}Sicherheitsabschaltung durch Optionskarte oder RECERBO hat ausgelöst
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;416&amp;#39; ) %}Kommunikation zwischen Leistungsteil und Steuerung nicht möglich.
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;417&amp;#39; ) %}ID-Problem der Hardware
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;419&amp;#39; ) %}Uniqe-ID Konflikt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;420&amp;#39; ) %}Kommunikation mit dem Hybridmanager nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;421&amp;#39; ) %}Fehler HID-Range
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;425&amp;#39; ) %}Kommunikation mit dem Leistungsteil ist nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;426&amp;#39; ) %}Möglicher Hardware-Defekt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;427&amp;#39; ) %}Möglicher Hardware-Defekt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;428&amp;#39; ) %}Möglicher Hardware-Defekt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;431&amp;#39; ) %}Software-Problem
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;436&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;437&amp;#39; ) %}Leistungsteil-Problem
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;438&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;443&amp;#39; ) %}Zwischenkreis-Spannung zu gering oder unsymetrisch
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;445&amp;#39; ) %}Kompatibilitätsfehler (z.B. auf Grund eines Print-Austausches) oder ungültige Leistungsteil-Konfiguration
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;447&amp;#39; ) %}Isolationsfehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;448&amp;#39; ) %}Neutralleiter nicht angeschlossen
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;450&amp;#39; ) %}Guard kann nicht gefunden werden
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;451&amp;#39; ) %}Speicherfehler entdeckt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;452&amp;#39; ) %}Kommunikationsfehler zwischen den Prozessoren
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;453&amp;#39; ) %}Netzspannung und Leistungsteil stimmen nicht überein
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;454&amp;#39; ) %}Netzfrequenz und Leistungsteil stimmen nicht überein
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;456&amp;#39; ) %}Anti-Islanding-Funktion wird nicht mehr korrekt ausgeführt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;457&amp;#39; ) %}Netzspannungsrelais-Fehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;458&amp;#39; ) %}Fehler bei der Mess-Signalerfassung
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;459&amp;#39; ) %}Fehler bei der Erfassung des Mess-Signals für den Isolationstest
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;460&amp;#39; ) %}Referenz-Spannungsquelle für den digitalen Signalprozessor (DSP) arbeitet außerhalb der tolerierten Grenzen
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;461&amp;#39; ) %}Fehler im DSP-Datenspeicher
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;462&amp;#39; ) %}Fehler bei der DC-Einspeisungs-Überwachungsroutine
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;463&amp;#39; ) %}Polarität AC vertauscht, AC-Verbindungsstecker falsch eingesteckt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;474&amp;#39; ) %}RCMU-Sensor defekt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;475&amp;#39; ) %}Isolationsfehler (Verbindung zwischen Solarmodul und Erdung)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;476&amp;#39; ) %}Versorgungsspannung der Treiberversorgung zu gering
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;479&amp;#39; ) %}Zwischenkreis-Spannungsrelais hat ausgeschaltet
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;480&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;481&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;482&amp;#39; ) %}Setup nach der erstmaligen Inbetriebnahme wurde abgebrochen
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;483&amp;#39; ) %}Spannung U (DCfix) beim MPP2-String liegt außerhalb des gültigen Bereichs
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;485&amp;#39; ) %}CAN Sende-Buffer ist voll
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;489&amp;#39; ) %}Permanente Überspannung am Zwischenkreis-Kondensator (5x hintereinander Statusmeldung 479)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;502&amp;#39; ) %}Isolationsfehler an den Solarmodulen
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;509&amp;#39; ) %}Keine Einspeisung innerhalb der letzten 24 Stunden
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;515&amp;#39; ) %}Kommunikation mit Filter nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;516&amp;#39; ) %}Kommunikation mit der Speichereinheit nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;517&amp;#39; ) %}Leistungs-Derating auf Grund zu hoher Temperatur
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;518&amp;#39; ) %}Interne DSP-Fehlfunktion
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;519&amp;#39; ) %}Kommunikation mit der Speichereinheit nicht möglich
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;520&amp;#39; ) %}Keine Einspeisung innerhalb der letzten 24 Stunden von MPPT1
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;522&amp;#39; ) %}DC low String 1
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;523&amp;#39; ) %}DC low String 2
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;558&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;559&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;560&amp;#39; ) %}Leistungs-Derating wegen Überfrequenz
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;564&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;566&amp;#39; ) %}Arc Detector ausgeschaltet (z.B. bei externer LichtbogenÜberwachung)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;568&amp;#39; ) %}fehlerhaftes Eingangssignal an der Multifunktions-Stromschnittstelle
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;572&amp;#39; ) %}Leistungslimitierung durch das Leistungsteil
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;573&amp;#39; ) %}Untertemperatur Warnung
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;581&amp;#39; ) %}Setup Special Purpose Utility-Interactive (SPUI) ist aktiviert
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;601&amp;#39; ) %}CAN Bus ist voll
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;603&amp;#39; ) %}Temperatursensor AC Modul defekt (L3)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;604&amp;#39; ) %}Temperatursensor DC Modul defekt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;607&amp;#39; ) %}RCMU Fehler
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;608&amp;#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;705&amp;#39; ) %}Konflikt beim Einstellen der Wechselrichter-Nummer (z.B. Nummer doppelt vergeben)
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;721&amp;#39; ) %}EEPROM wurde neu initialisiert 
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;731&amp;#39; ) %}Initialisierungsfehler - USB-Stick wird nicht unterstützt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;732&amp;#39; ) %}Initialisierungsfehler - Überstrom am USB-Stick
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;733&amp;#39; ) %}Kein USB-Stick angesteckt
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;734&amp;#39; ) %}Update-Datei wird nicht erkannt oder ist nicht vorhanden
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;735&amp;#39; ) %}nicht zum Gerät passende Update-Datei, zu alte Update-Datei
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif is_state(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;, &amp;#39;736&amp;#39; ) %}Schreib- oder Lesefehler aufgetreten
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% elif states.sensor.status_code_fronius_inverter and states(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;) | int &amp;lt; 100 %}OK
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% else %}Unbekannter Status
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% endif %}&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;w&#34;&gt;        &lt;/span&gt;&lt;span class=&#34;nt&#34;&gt;icon&lt;/span&gt;&lt;span class=&#34;p&#34;&gt;:&lt;/span&gt;&lt;span class=&#34;w&#34;&gt; &lt;/span&gt;&lt;span class=&#34;p&#34;&gt;&amp;gt;&lt;/span&gt;&lt;span class=&#34;sd&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% if states.sensor.status_code_fronius_inverter and states(&amp;#39;sensor.status_code_fronius_inverter&amp;#39;) | int &amp;lt; 100 %}
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;            mdi:weather-sunset-up
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% else %}
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;            mdi:alert-octagram
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span class=&#34;line&#34;&gt;&lt;span class=&#34;cl&#34;&gt;&lt;span class=&#34;sd&#34;&gt;          {% endif %}&lt;/span&gt;&lt;span class=&#34;w&#34;&gt;
&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/code&gt;&lt;/pre&gt;&lt;/td&gt;&lt;/tr&gt;&lt;/table&gt;
&lt;/div&gt;
&lt;/div&gt;</description>
      
         <content:encoded><![CDATA[<p>Vor einiger Zeit habe ich für meinen Fronius Solar Wechselrichter ein Template in Home-Assistant für eine Übersetzung des Status Codes gebaut.
<ins class="adsbygoogle" style="display:block; text-align:center;" data-ad-layout="in-article" data-ad-format="fluid" data-ad-client="ca-pub-2322978122735420" data-ad-slot="3161252284"></ins>
Damit bekommt man nicht nur kryptische Zahlen ausgeworfen, sondern kann sogar was damit anfangen ;-) Im Untenstehenden Template musst du nur deinen sensor für den Status Code statt meinem <code>sensor.status_code_fronius_inverter</code> eintragen.</p>
<div class="highlight"><div class="chroma">
<table class="lntable"><tr><td class="lntd">
<pre tabindex="0" class="chroma"><code><span class="lnt">  1
</span><span class="lnt">  2
</span><span class="lnt">  3
</span><span class="lnt">  4
</span><span class="lnt">  5
</span><span class="lnt">  6
</span><span class="lnt">  7
</span><span class="lnt">  8
</span><span class="lnt">  9
</span><span class="lnt"> 10
</span><span class="lnt"> 11
</span><span class="lnt"> 12
</span><span class="lnt"> 13
</span><span class="lnt"> 14
</span><span class="lnt"> 15
</span><span class="lnt"> 16
</span><span class="lnt"> 17
</span><span class="lnt"> 18
</span><span class="lnt"> 19
</span><span class="lnt"> 20
</span><span class="lnt"> 21
</span><span class="lnt"> 22
</span><span class="lnt"> 23
</span><span class="lnt"> 24
</span><span class="lnt"> 25
</span><span class="lnt"> 26
</span><span class="lnt"> 27
</span><span class="lnt"> 28
</span><span class="lnt"> 29
</span><span class="lnt"> 30
</span><span class="lnt"> 31
</span><span class="lnt"> 32
</span><span class="lnt"> 33
</span><span class="lnt"> 34
</span><span class="lnt"> 35
</span><span class="lnt"> 36
</span><span class="lnt"> 37
</span><span class="lnt"> 38
</span><span class="lnt"> 39
</span><span class="lnt"> 40
</span><span class="lnt"> 41
</span><span class="lnt"> 42
</span><span class="lnt"> 43
</span><span class="lnt"> 44
</span><span class="lnt"> 45
</span><span class="lnt"> 46
</span><span class="lnt"> 47
</span><span class="lnt"> 48
</span><span class="lnt"> 49
</span><span class="lnt"> 50
</span><span class="lnt"> 51
</span><span class="lnt"> 52
</span><span class="lnt"> 53
</span><span class="lnt"> 54
</span><span class="lnt"> 55
</span><span class="lnt"> 56
</span><span class="lnt"> 57
</span><span class="lnt"> 58
</span><span class="lnt"> 59
</span><span class="lnt"> 60
</span><span class="lnt"> 61
</span><span class="lnt"> 62
</span><span class="lnt"> 63
</span><span class="lnt"> 64
</span><span class="lnt"> 65
</span><span class="lnt"> 66
</span><span class="lnt"> 67
</span><span class="lnt"> 68
</span><span class="lnt"> 69
</span><span class="lnt"> 70
</span><span class="lnt"> 71
</span><span class="lnt"> 72
</span><span class="lnt"> 73
</span><span class="lnt"> 74
</span><span class="lnt"> 75
</span><span class="lnt"> 76
</span><span class="lnt"> 77
</span><span class="lnt"> 78
</span><span class="lnt"> 79
</span><span class="lnt"> 80
</span><span class="lnt"> 81
</span><span class="lnt"> 82
</span><span class="lnt"> 83
</span><span class="lnt"> 84
</span><span class="lnt"> 85
</span><span class="lnt"> 86
</span><span class="lnt"> 87
</span><span class="lnt"> 88
</span><span class="lnt"> 89
</span><span class="lnt"> 90
</span><span class="lnt"> 91
</span><span class="lnt"> 92
</span><span class="lnt"> 93
</span><span class="lnt"> 94
</span><span class="lnt"> 95
</span><span class="lnt"> 96
</span><span class="lnt"> 97
</span><span class="lnt"> 98
</span><span class="lnt"> 99
</span><span class="lnt">100
</span><span class="lnt">101
</span><span class="lnt">102
</span><span class="lnt">103
</span><span class="lnt">104
</span><span class="lnt">105
</span><span class="lnt">106
</span><span class="lnt">107
</span><span class="lnt">108
</span><span class="lnt">109
</span><span class="lnt">110
</span><span class="lnt">111
</span><span class="lnt">112
</span><span class="lnt">113
</span><span class="lnt">114
</span><span class="lnt">115
</span><span class="lnt">116
</span></code></pre></td>
<td class="lntd">
<pre tabindex="0" class="chroma"><code class="language-yaml" data-lang="yaml"><span class="line"><span class="cl"><span class="nn">---</span><span class="w">
</span></span></span><span class="line"><span class="cl"><span class="nt">template</span><span class="p">:</span><span class="w">
</span></span></span><span class="line"><span class="cl"><span class="w">  </span>- <span class="nt">sensor</span><span class="p">:</span><span class="w">
</span></span></span><span class="line"><span class="cl"><span class="w">      </span>- <span class="nt">name</span><span class="p">:</span><span class="w"> </span><span class="s2">&#34;Fronius Status Message&#34;</span><span class="w">
</span></span></span><span class="line"><span class="cl"><span class="w">        </span><span class="nt">state</span><span class="p">:</span><span class="w"> </span><span class="p">&gt;</span><span class="sd">
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% if is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;102&#39; ) %}AC-Spannung zu hoch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;103&#39; ) %}AC-Spannung zu gering
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;105&#39; ) %}AC-Frequenz zu hoch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;106&#39; ) %}AC-Frequenz zu gering
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;107&#39; ) %}AC-Netz nicht vorhanden
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;108&#39; ) %}Inselbetrieb erkannt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;112&#39; ) %}Fehler RCMU
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;301&#39; ) %}Überstrom (AC) 
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;302&#39; ) %}Überstrom (DC)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;303&#39; ) %}Übertemperatur DC Modul
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;304&#39; ) %}Übertemperatur AC Modul
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;305&#39; ) %}Keine Einspeisung trotz geschlossener Relais
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;306&#39; ) %}Es steht zu wenig PV-Leistung für den Einspeisebetrieb zur Verfügung
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;307&#39; ) %}DC-Eingangsspannung zu gering für den Einspeisebetrieb
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;308&#39; ) %}Zwischenkreisspannung zu hoch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;309&#39; ) %}DC-Eingangsspannung MPPT 1 zu hoch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;311&#39; ) %}DC-Stränge verpolt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;313&#39; ) %}DC-Eingangsspannung MPPT2 zu hoch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;314&#39; ) %}Timeout Stromsensor-Kalibrierung
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;315&#39; ) %}AC Stromsensor Fehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;316&#39; ) %}InterruptCheck fail
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;325&#39; ) %}Übertemperatur im Anschlussbereich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;326&#39; ) %}Lüfter 1 Fehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;327&#39; ) %}Lüfter 2 Fehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;401&#39; ) %}Kommunikation mit dem Leistungsteil nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;406&#39; ) %}Temperatursensor AC Modul defekt (L1)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;407&#39; ) %}Temperatursensor AC Modul defekt (L2)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;408&#39; ) %}Zu hoher Gleichanteil im Versorgungsnetz gemessen
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;412&#39; ) %}Der Fix-Spannungsbetrieb ist statt des MPP-Spannungsbetriebes angewählt und die Fixspannung ist auf einen zu geringen oder zu hohen Wert eingestellt.
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;415&#39; ) %}Sicherheitsabschaltung durch Optionskarte oder RECERBO hat ausgelöst
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;416&#39; ) %}Kommunikation zwischen Leistungsteil und Steuerung nicht möglich.
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;417&#39; ) %}ID-Problem der Hardware
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;419&#39; ) %}Uniqe-ID Konflikt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;420&#39; ) %}Kommunikation mit dem Hybridmanager nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;421&#39; ) %}Fehler HID-Range
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;425&#39; ) %}Kommunikation mit dem Leistungsteil ist nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;426&#39; ) %}Möglicher Hardware-Defekt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;427&#39; ) %}Möglicher Hardware-Defekt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;428&#39; ) %}Möglicher Hardware-Defekt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;431&#39; ) %}Software-Problem
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;436&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;437&#39; ) %}Leistungsteil-Problem
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;438&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;443&#39; ) %}Zwischenkreis-Spannung zu gering oder unsymetrisch
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;445&#39; ) %}Kompatibilitätsfehler (z.B. auf Grund eines Print-Austausches) oder ungültige Leistungsteil-Konfiguration
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;447&#39; ) %}Isolationsfehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;448&#39; ) %}Neutralleiter nicht angeschlossen
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;450&#39; ) %}Guard kann nicht gefunden werden
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;451&#39; ) %}Speicherfehler entdeckt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;452&#39; ) %}Kommunikationsfehler zwischen den Prozessoren
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;453&#39; ) %}Netzspannung und Leistungsteil stimmen nicht überein
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;454&#39; ) %}Netzfrequenz und Leistungsteil stimmen nicht überein
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;456&#39; ) %}Anti-Islanding-Funktion wird nicht mehr korrekt ausgeführt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;457&#39; ) %}Netzspannungsrelais-Fehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;458&#39; ) %}Fehler bei der Mess-Signalerfassung
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;459&#39; ) %}Fehler bei der Erfassung des Mess-Signals für den Isolationstest
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;460&#39; ) %}Referenz-Spannungsquelle für den digitalen Signalprozessor (DSP) arbeitet außerhalb der tolerierten Grenzen
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;461&#39; ) %}Fehler im DSP-Datenspeicher
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;462&#39; ) %}Fehler bei der DC-Einspeisungs-Überwachungsroutine
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;463&#39; ) %}Polarität AC vertauscht, AC-Verbindungsstecker falsch eingesteckt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;474&#39; ) %}RCMU-Sensor defekt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;475&#39; ) %}Isolationsfehler (Verbindung zwischen Solarmodul und Erdung)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;476&#39; ) %}Versorgungsspannung der Treiberversorgung zu gering
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;479&#39; ) %}Zwischenkreis-Spannungsrelais hat ausgeschaltet
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;480&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;481&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;482&#39; ) %}Setup nach der erstmaligen Inbetriebnahme wurde abgebrochen
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;483&#39; ) %}Spannung U (DCfix) beim MPP2-String liegt außerhalb des gültigen Bereichs
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;485&#39; ) %}CAN Sende-Buffer ist voll
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;489&#39; ) %}Permanente Überspannung am Zwischenkreis-Kondensator (5x hintereinander Statusmeldung 479)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;502&#39; ) %}Isolationsfehler an den Solarmodulen
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;509&#39; ) %}Keine Einspeisung innerhalb der letzten 24 Stunden
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;515&#39; ) %}Kommunikation mit Filter nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;516&#39; ) %}Kommunikation mit der Speichereinheit nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;517&#39; ) %}Leistungs-Derating auf Grund zu hoher Temperatur
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;518&#39; ) %}Interne DSP-Fehlfunktion
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;519&#39; ) %}Kommunikation mit der Speichereinheit nicht möglich
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;520&#39; ) %}Keine Einspeisung innerhalb der letzten 24 Stunden von MPPT1
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;522&#39; ) %}DC low String 1
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;523&#39; ) %}DC low String 2
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;558&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;559&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;560&#39; ) %}Leistungs-Derating wegen Überfrequenz
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;564&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;566&#39; ) %}Arc Detector ausgeschaltet (z.B. bei externer LichtbogenÜberwachung)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;568&#39; ) %}fehlerhaftes Eingangssignal an der Multifunktions-Stromschnittstelle
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;572&#39; ) %}Leistungslimitierung durch das Leistungsteil
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;573&#39; ) %}Untertemperatur Warnung
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;581&#39; ) %}Setup Special Purpose Utility-Interactive (SPUI) ist aktiviert
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;601&#39; ) %}CAN Bus ist voll
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;603&#39; ) %}Temperatursensor AC Modul defekt (L3)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;604&#39; ) %}Temperatursensor DC Modul defekt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;607&#39; ) %}RCMU Fehler
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;608&#39; ) %}Funktions-Inkompatibilität (einer oder mehrere Prints im Wechselrichter sind nicht kompatibel zueinander, z.B. nach einem Print-Austausch)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;705&#39; ) %}Konflikt beim Einstellen der Wechselrichter-Nummer (z.B. Nummer doppelt vergeben)
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;721&#39; ) %}EEPROM wurde neu initialisiert 
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;731&#39; ) %}Initialisierungsfehler - USB-Stick wird nicht unterstützt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;732&#39; ) %}Initialisierungsfehler - Überstrom am USB-Stick
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;733&#39; ) %}Kein USB-Stick angesteckt
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;734&#39; ) %}Update-Datei wird nicht erkannt oder ist nicht vorhanden
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;735&#39; ) %}nicht zum Gerät passende Update-Datei, zu alte Update-Datei
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif is_state(&#39;sensor.status_code_fronius_inverter&#39;, &#39;736&#39; ) %}Schreib- oder Lesefehler aufgetreten
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% elif states.sensor.status_code_fronius_inverter and states(&#39;sensor.status_code_fronius_inverter&#39;) | int &lt; 100 %}OK
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% else %}Unbekannter Status
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% endif %}</span><span class="w">
</span></span></span><span class="line"><span class="cl"><span class="w">        </span><span class="nt">icon</span><span class="p">:</span><span class="w"> </span><span class="p">&gt;</span><span class="sd">
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% if states.sensor.status_code_fronius_inverter and states(&#39;sensor.status_code_fronius_inverter&#39;) | int &lt; 100 %}
</span></span></span><span class="line"><span class="cl"><span class="sd">            mdi:weather-sunset-up
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% else %}
</span></span></span><span class="line"><span class="cl"><span class="sd">            mdi:alert-octagram
</span></span></span><span class="line"><span class="cl"><span class="sd">          {% endif %}</span><span class="w">
</span></span></span></code></pre></td></tr></table>
</div>
</div>]]></content:encoded>
    </item>
  </channel>
</rss>
